Full-Scale Measurements on Vibrations of a 51-Story Tall Building Due to a Major Earthquake and Typhoon

Article Preview

Abstract:

The Shin Kong Tower located in Taipei City has a height of 244.15 m. It was the tallest building in northern Taiwan when it was built in 1993. This super tall building is susceptible to severe vibrations induced by strong winds or earthquakes. Safety of the building structures and its contents as well as the comfort of its occupants under such strong forces remains a significant engineering concern. Records by a structural array in the 51-story SK Building of the 1999 M7.6 Chi-Chi earthquake and 2004 Typhoon Aere are analyzed in this study. As a result, the structural dynamic characteristics of the high-rise building, including the transfer functions and natural frequencies, excited by the Chi-Chi earthquake, Typhoon Aere, and ambient vibrations are also determined and compared.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1259-1263

Citation:

Online since:

January 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] C.C. Wu and Y.H. Kao: Typhoons affecting Taiwan: Current understanding and future challenges. Bull. Amer. Meteor. Soc.Vol. 80 (1999), p.67.

DOI: 10.1175/1520-0477(1999)080<0067:tatcua>2.0.co;2

Google Scholar

[2] Y.L. Xu and S. Zhan: Field measurements of Di Wang Tower during Typhoon York. J. Wind Eng. Ind. Aerodyn Vol. 89 (2001), p.73.

DOI: 10.1016/s0167-6105(00)00029-5

Google Scholar

[3] Q.S. Li, J.Q. Fang, A.P. Jeary and C.K. Wong: Full scale measurement of wind effects on tall buildings. Journal of Winf Engineering and Industrial Aerodynamics Vol. 74-76 (1998), p.741.

DOI: 10.1016/s0167-6105(98)00067-1

Google Scholar

[4] T.L. Teng: Technical report on design and implementation of a prototype realtime strong-motion array system, Southern California Earthquake Center, University of Southern California, Los Angeles, CA 90089-0740 (1992).

Google Scholar

[5] T.C. Shin and T.L. Teng: An overview of the 1999 Chi-Chi, Taiwan, Earthquake. Bull. Seis. Soc. Am. Vol.91 (2001), p.895.

Google Scholar

[6] C.H. Loh and H.M. Lin: Application of off-line and on-line identification techniques to building seismic response data. Earthquake Engineering and Structural Dynamics Vol. 25 (1996), p.269.

DOI: 10.1002/(sici)1096-9845(199603)25:3<269::aid-eqe554>3.0.co;2-j

Google Scholar

[7] J.L. Beck and P.C. Jennings: Structural identification using linear modals and earthquake records. Earthquake Engineering and Structural Dynamics.Vol.8 (1980), p.145.

DOI: 10.1002/eqe.4290080205

Google Scholar

[8] Y. Li and S.T. Mau: Anatomy of the Loma Prieta earthquake records of two steel buildings using MIMO system identification. Proc., Conf. Engrg. Mech., ASCE, New York. (1992), p.689.

Google Scholar

[9] K.C. Tsai, C.H. Loh, C.H. Yeh and C.M. Su: Design examples and the recommended modifications on the tentative seismic force provisions for building structures in Taiwan. Architecture & Building Institute, Ministry of Interior Research Project Report. Taipei. (2001).

Google Scholar