The Non-Invasive Measurement of Geometry of Human Ossicles

Article Preview

Abstract:

This study is to reconstruct the 3D model of ossicles by the smoothing technique that fitted to the human ossicles. The length of the geometry of the model was then measured. The image of human ossicles was obtained by the micro computed tomography scan. The 3D model of human ossicles was reconstructed by image processing, and then the length of the geometry of the 3D model was measured. The 3D model of human ossicles was reconstructed by image processing and by surface smoothing technique in this study. The surface of the ossicles model was smoothed by Smoothsurface. The length of the short process of the incus was 1.8 mm. The length of the long process of the incus was 5.2 mm. Based on the results obtained by this study, there was almost no difference for the measurements of the lengths of the cadaver malleus and incus between by observation and by image processing. Therefore, the image processing method was convenient and reliable. By the 3D model of ossicles, the clinician could know the structure of middle ear and could diagnose the middle ear disease more exactly.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1569-1573

Citation:

Online since:

January 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Nomura, Y., Hiraide, F. and Harada, T., New Atlas of Otology, Springer-Verlag, Tokyo. (1992).

Google Scholar

[2] William A. Yost, Fundamentals of hearing, Academic Press, fourth edition, (2000).

Google Scholar

[3] Sun Q, Gan RZ, Chang KH, Dormer KJ. Computer-integrated finite element modeling of human middle ear. Biomech Model Mechanobiol 1: 109-122. (2002).

DOI: 10.1007/s10237-002-0014-z

Google Scholar

[4] Decraemer WF, Dirckx JJ, Funnell WR. Three-dimensional modelling of the middle-ear ossicular chain using a commercial high-resolution X-ray CT scanner. J Assoc Res Otolaryngol 4: 250-263. (2003).

DOI: 10.1007/s10162-002-3030-x

Google Scholar

[5] Lee CF, Chen PR, Lee WJ, Chen JH, Liu TC. Three-dimensional reconstruction and modeling of middle ear biomechanics by high-resolution computed tomography and finite element analysis. Laryngoscope 116: 711-716. (2006).

DOI: 10.1097/01.mlg.0000204758.15877.34

Google Scholar

[6] Jen-Fang Yu, Ching-I Chen, Chia-Lun Fan, Chin-Kuo Chen, Smoothing for the optimal surface of a 3D image model of the human ossicles. Journal of Mechanics, 5; 41(16): 3515-8. (2010).

Google Scholar