Background Leakage of Pressure Leak Calibration Caused by Temperature Change

Article Preview

Abstract:

On laboratory conditions,background leakage caused by temperature change was one of the most important factors for affecting calibration of pressure leak, consequently, the constant temperature water bath of the calibration apparatus has been used to reduce background leakage by means of keeping the apparatus temperature constant. The method of active and passiveness were combined to keep constant temperature. through the research on experimentation, it was found that background leakage was decreased to the grade of 1.36×10-9Pam3/s when constant temperature been used, and meanwhile the lower limiting of pressure leak was extended to 2.667×10-8Pam3/s.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

339-343

Citation:

Online since:

February 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Cao Shencheng, Liu Zhidong, FengYiming. the method of Pressure leak check by helium mass spectrum. Vacuum and Cryogenice[J]. 2000, 6(1): 58-60, In Chinese.

Google Scholar

[2] DindQin, SuWen, ZhaoHu. Ocean No 1, secondary planet leakage checktechnology. Spacecraft Environment Engineering[J]. 2002, 19(1): 35-41, In Chinese.

Google Scholar

[3] Zhang Xiaoyi, CaoJun, CuiZhihe, WangFan, YangJianhua. speediness check the leak of port. P721-724, In Chinese.

Google Scholar

[4] Yan Rongxin, XiaoXiangzheng, ZhaoDingzhong. leakage changed by temperature, Vacuum and cryogenice[J]. 1995, 1(1): 12-15, In Chinese.

Google Scholar

[5] FengYan, ZhangDixin, LiDetian, ShengXuemin. Calibration Method of Pressure Leak. Measure Technology[J]. 2010, 30(2): 1-5, In Chinese.

Google Scholar

[6] FengYan, ZhangDixin, ChengYongjun. Optimial design of pressure leak calibration system, Vacuum[J]. 2009, 46(3): 72-75, In Chinese.

Google Scholar

[7] FengYan, ZhangDixin. Design of pressure leak calibrator in constant pressure mode. Chinese journal of vacuum science and technology[J]. 2007, 27(5): 442-445.

Google Scholar

[8] National defence science industry and quality, In Chinese.

Google Scholar

[9] Commission of science technology ang industry for national defense. metrologicalteaching material-mechanics [M]. atomic energy press, 2002, In Chinese.

Google Scholar

[10] Karl Jousten, Ute Becker. A primary standard for the calibrafion of sniffer test leak devices[J]. Metrologia. 2009(46): 560-568.

DOI: 10.1088/0026-1394/46/5/021

Google Scholar