Locating Method of Single-Phase Grounding Fault in Small Current Grounding System Based on Distribution Automation

Article Preview

Abstract:

In case of the arc suppression coil for neutral point grounding of small current grounding system, when single-phase grounding fault occurs, due to the arc suppression coil for fault line of the compensation effect of the zero sequence current, the fault features is not obvious, it can't implement the fault line selection and fault point location. This paper puts forward a method of change fault lines zero sequence current shortly, namely a resistance inductance (RL) series branch parallel in arc suppression coil, the series branch acts on the system shortly and changes arc suppression coil compensation degree temporarily in single-phase grounding fault. The change of zero sequence residual current only appears the loop from the neutral point to the fault point via the fault line, using FTU (feeder terminal units) on lines monitor the change of zero sequence current on each nodes for fault regional location. And prove this theory the feasibility of the by using MATLAB software of system modeling simulation method.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1423-1428

Citation:

Online since:

June 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] LIU Jian, NI Jian-li, DENG Yong-hui. Distribution automation system[M]. Beijing: China Water Resources and Hydro electrical Press, 1999. In Chinese.

Google Scholar

[2] XIAO Bai, SHU Hong-chun, GAO Feng. Survey Methods of Fault Line Selection for Single-phase-to-earth Fault in Networks with Ungrounded Neutral[J]. Relay, 2001, 29(4):17-20. In Chinese.

DOI: 10.1109/icpst.2002.1047242

Google Scholar

[3] WANG Zheng, WU Jie. Method of Single Phase Grounding Fault Locating for FTU in Networks with Ungrounded Neutral[J]. Electric Power Automation Equipment, 2003, 23(2):21-26. In Chinese.

Google Scholar

[4] WU Jie, WANG Zheng. Reinvestigation for Approaches to Fault Location based on FTU in Power System with Neutral Unearthed[J]. Relay, 2004, 32(22):29-33. In Chinese.

Google Scholar

[5] JIA Qing-quan, YANG Yi-han, YANG Qi-xun. Application of DS Evidence Theory to Single-phase-to-ground Fault Line Detection[J]. Automation of Electric Power Systems, 2003, 27(21): 25-38. In Chinese.

Google Scholar

[6] LIU Daobing, GU Xueping. Locating Technique of Single-phase Grounding Fault based on Distribution Automation[J]. Automation of Electric Power Systems, 2010, 34(5): 77-50. In Chinese.

Google Scholar

[7] ZENG Xiang-jun, LI K K, CHAN W L, et al. Earth Fault Feeder Detection with Information Fusion. Relay, 2002,30(9)15-20. In Chinese.

Google Scholar

[8] Kezunovic MJ, Mrkic B Perunicic. An Accurate Fault Location Algorithm Using Synchronized Sampling[J]. Electric Power Systems Research, 1994, 29(3): 161-169.

DOI: 10.1016/0378-7796(94)90011-6

Google Scholar