A high amplitude, fast rising time, and high isolating strength trigger signal is needed for triggering spark gap switch. A high voltage power supply scheme was verified by means of simulation in this paper. Proper parameters of power supply circuit were selected according to the simulation result. Finally, a pulsed power supply was developed. The experimental results show that a negative pulse with 25 kV isolating strength and 15 kV amplitude can be generated by the power supply, and this generated negative pulse can meet the demand of triggering spark gap switch.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1429-1433

Citation:

Online since:

June 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Wang Renli, Liao Minfu, Kong Fandong, et al., Research on Sterilization of Pulsed Generator in HPEF Fixed Chamber. High voltage engineering, 2007. 33(02): pp.82-85. (in Chinese)

Google Scholar

[2] Fan Chuanyan, and Chen Meiran, The Design of Controllers for High-frequency and High-voltage Pulse Power Used in Crude Oil Electric Dehydration. Automation in Petro-Chemical Industry, 2011. 47(02): pp.48-50. (in Chinese)

Google Scholar

[3] Liu, Y., et al., Design and Construction of a Trigger Generator Based on Pulse Transformer for Spark Gap Switch. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2011. 39(12): pp.3378-3385.

DOI: 10.1109/tps.2011.2167987

Google Scholar

[4] Cheng Xinbing, Liu Jinliang, Chen Zheng, et al., Operating Characteristics of a Heavy Current Three-electrode Gas Spark Switch. High voltage engineering, 2009. 35(07): pp.1689-1694. (in Chinese)

Google Scholar

[5] Zhu Hongzhi, Yang Yonghui, and Liu Wei, Pspice Simulation of High Voltage Ignition Power Supply. Power Electronics, 2011. 45(09): pp.5-6+9. (in Chinese)

Google Scholar

[6] Zhang Zhaohua, Research on the Design of High2voltage Isolated Pulse Transformer. RADAR and ECM, 2002(3): pp.61-64. (in Chinese)

Google Scholar

[7] Yang Yu, Wu Youcheng, Geng Lidong, et al., The Investigation of the Pulse over Low-impedance Load Excited by Electric Exploding Wire and Pulse Transformer. High Voltage Apparatus, 2010. 46(02): pp.39-41. (in Chinese)

Google Scholar

[8] Zhong Guochen, PSpice circuit design and application. 2007, Beijing: National Defense Industrial Press. (in Chinese)

Google Scholar