The Study of On-Line Fiber Optic Monitoring for Pressure Component

Article Preview

Abstract:

The application of the distributed optical-fiber detection system and optical fiber grating detection system in the laboratory piping system leakage platform, was analyzed in this paper. Based on the on-line monitoring tests, the potential advantages and disadvantages of optical-fiber method using for engineering structures were summarized. The implementation method on the optical-fiber monitoring methods for pressure vessel and industrial piping system in service was proposed in the end.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

460-464

Citation:

Online since:

June 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Brunone B.Transient test-based technique for leak detection in outfall Pipes. Journal of Water Resources Planning and Management. 1999, 125(5):302-306

DOI: 10.1061/(asce)0733-9496(1999)125:5(302)

Google Scholar

[2] Ferrante, Macro, Brunone, Bruno. Pipe system diagnosis and leak detection by unsteady-state tests.1. Harmonic analysis. Advances in Water Resources. 2003,26(1). 95-105

DOI: 10.1016/s0309-1708(02)00101-x

Google Scholar

[3] Shiwen Jin, Lining Wang. The leakage location technology of crude oil pipeline. ACTC PETROLEI SINICA. 1998.19(3):93-98

Google Scholar

[4] QIAO Yingxin, LI Jianhua, HE Yueguang. Application and Prospect of Fiber Optic Monitoring Technology in Civil Engineering. Journal of Nanchang Institute of Technology. 2007,26(1):13-18

Google Scholar

[5] ZHANG Enyong, JIN Weiliang, SONG Mouping. Distributed Optical Fiber Monitoring System In-series for Submarine Pipeline. China's Marine platform. 2004.19(5):40-43

Google Scholar

[6] Hu Sheng, Shi Bin, Wei Guangqing. Experimental Study on Deformation Monitoring of PE Pipelines with Distributed Optical-Fiber. Journal of Disaster Prevention and Mitigation Engineering. 2008.28(4):436-453

Google Scholar

[7] Bin Wu, Dongsheng Cai, Lijun Hang.Development of pipeline leakage detection software based on LabVIEW platform.Chinese Journal of Scientific Instrument. 2008.29(10):2096-2099

Google Scholar

[8] Shuchun Cheng,Yanping Zhang. Application of fiber grating sensor for oil leak detection in oil industry. Journal of Applied Optics.2008.29(3)440-443:

Google Scholar

[9] Chunshu Zhang, Xiaoyi Bao, Istemi F. Ozkan. Prediction of the pipe buckling by using broadening factor with distributed Brillouin fiber sensors. Optical Fiber Technology 14.(2008). 109-113

DOI: 10.1016/j.yofte.2007.09.005

Google Scholar