Study of Crack Identifications in Coupling Beam Based on the EMI and ANN Techniques

Article Preview

Abstract:

Based on EMI and ANN techniques, crack location in coupling beam was studied by the experimental platform which using the WK6500 impedance analyzer. Impedance curves of the different PZT was obtained to diagnosis the situation of coupling beam whether it was perfect or cracked, and then located the crack by neural network technique to if the coupling beam was cracked.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1625-1628

Citation:

Online since:

July 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Lin B, Giurgiutiu V. On the modeling of piezoelectric wafer active sensor impedance analysis for structural health monitoring: Smart Structures and Materials (2006).

DOI: 10.1117/12.658521

Google Scholar

[2] Zhang J, Qin G. The study on piezoelectric impedance technique used in loading damage identification: 2010 International Conference on Manufacturing Engineering and Automation, ICMEA2010, December 7, 2010 - December 9, 2010, Guangzhou, China, 2010[C]. Trans Tech Publications.

Google Scholar

[3] Shen X, Lv J, Zhang J, et al. Experiment of structural health monitoring based on piezoelectric impedance technology and BP network[J]. Nanjing Hangkong Hangtian Daxue Xuebao/Journal of Nanjing University of Aeronautics and Astronautics, 2010, 42(4): 418-422.

Google Scholar