Duty Ratio Thresholds for Regular Transmission at Human Tissue of Near-Infrared Square-Wave Pulse

Article Preview

Abstract:

In order to understand the transmission mechanism at human tissue of near-infrared square-wave pulse (NIRSP), an experimental study of the duty ratio threshold for regular transmission at the fingertip and palm of human hand by NIRSP was carried out by using a couple of simple transmitting and receiving device with tunable duty ratios, and also the light emitting diodes (LED) both at the wavelengths of 850 nm and 940 nm. The thresholds were determined by measuring the waveforms of the changed voltages of NIRSP receiving system as a measurement of the transmission at human tissue. When the receiving waveforms were taken on the certain behavior as the emitting waveforms, the duty ratio threshold for regular transmission at human tissue of NIRSP was observed. The experimental results show that the duty ratio is an important index for the transmission at human tissue of NIRSP. And the duty ratio thresholds for regular transmission both at the fingertip and palm of NIRSP at the wavelength of 850 nm and 940 nm have been given.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

555-558

Citation:

Online since:

July 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] D T Delpy, M Cope, P van der Zee, S Arridge, S Wray and J Wyatt. Estimation of optical pathlength through tissue from direct time of flight measurement. Physics in Medicine and Biology 33 (1988), pp.1433-1442.

DOI: 10.1088/0031-9155/33/12/008

Google Scholar

[2] Patrick W. McCormick, Melville Stewart, Gary Lewis, Manuel Dujovny, and James I. Ausman. Intra cerebral penetration of infrared light. Journal of Neurosurgery 76 (1992), pp.315-318.

DOI: 10.3171/jns.1992.76.2.0315

Google Scholar

[3] Jobsis FF. Non-invasive infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. Science 198 (1977), pp.1264-1267.

DOI: 10.1126/science.929199

Google Scholar

[4] H. Owen-Reece, M. Smith, C.E. Elwell, and J. C. Goldstone. Near infrared spectroscopy. British Journal of Anaesthesia 82 (1999), pp.418-426.

DOI: 10.1093/bja/82.3.418

Google Scholar

[5] Michael S. Patterson, B. Chance, and B.C. Wilson, Time-resolved reflectance and transmittance for the non-invasive measurement of tissue optical properties. Applied Optics 28 (1989), pp.231-236.

DOI: 10.1364/ao.28.002331

Google Scholar

[6] D. Pudiš, L'. Šušlik, J. Škriniarová, J. Kováč, I. Martinček, J. Kováč Jr., Š. Haščík, I. Kubicová, J. Novák and M. Veselý. Light extraction from a light emitting diode with photonic structure in the surface layer investigated by NSOM. Optics & Laser Technology 43 (2011).

DOI: 10.1016/j.optlastec.2011.01.004

Google Scholar

[7] B.S. Yilbas, S.Z. Shuja, S.M.A. Khan. Laser repetitive pulse heating of tool surface. Optics & Laser Technology 43 (2011), pp.754-761.

DOI: 10.1016/j.optlastec.2010.12.013

Google Scholar

[8] GAO Bo, WEI Wei, GONG Min, WANG Li. Near-infrared Spectral Study on Blood Oxygen Saturation in Multi-layer Tissue. Spectroscopy and Spectral Analysis 29 (2009), pp.2922-2925.

Google Scholar

[9] D T Deplpy, M Cope, P van Zee, S Arridge, S Wray and J Wyatt. Estimation of optical pathlength through tissue from direct time of flight measurement. Physics in Medicine and Biology 33 (1988), pp.1433-1442.

DOI: 10.1088/0031-9155/33/12/008

Google Scholar

[10] SONG Junjie, WANG Zhe, JIN Hailong, WANG Chao. Study and implement of three- wavelength oximeter to measure low oxygen saturation. LASER & INFRAED 40 (2010), pp.62-65.

Google Scholar