Finite Element Modal Analysis of the Quick Positioning System of Wire Bonders

Article Preview

Abstract:

The positioning system with high acceleration and high precision determines the speed and quality of bonding, which is the core component in a wire bonder, and influences the cost and reliability of the chip. The mode characteristics of the high acceleration and high precision positioning system were analyzed using ABAQUS. The results show that the system has different vibration characteristics in different resonance mode, and also has the features of mode denseness and complicated vibration mode.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1840-1844

Citation:

Online since:

October 2010

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2010 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Zhou S, Li Y T, Meng G and Ding H. Active vibaration control for arm structure undergoing high acceleration motion and precision position [J]. Mechanical Strength , 2006, 28(1): 6~12(in Chinese).

Google Scholar

[2] Chao T S and Tai L C. Optimizing the IC wire bonding process using a neural networks/genetic algorithms approach[J]. Intelligent Manufacturing, 2003, 14(2): 229~238.

Google Scholar

[3] Khouzema B Unchwaniwala and Michael F Caggiano. Electrical Analysis of IC Packaging with Emphasis on Different Ball Grid Array Packages [J]. Electronic Components and Technology Conference, (2001).

DOI: 10.1109/ectc.2001.928034

Google Scholar

[4] Ajit S Gaunekar, Gary P Widdowson, Narasimalu S andWang G N. Design and development of a high precision lens focusing mechanism using flexure bearings[J]. Precision Engineering, 2005, 29(1): 81~85.

DOI: 10.1016/j.precisioneng.2004.05.005

Google Scholar

[5] He T. The status and development trend of wire bonding technology [J]. Equipment for Electronic Products Manufacture, 2004, 117 (10): 12 ~ 14. ( in Chinese).

Google Scholar

[6] Zhong Z W and Goh K S. Investigation of ultrasonic vibrations of wire-bonding capillaries.

Google Scholar

[7] Jang C, Ahn G, Kim Y J , et al. Finite element contact analysis on a horn-holder assembly for wire bonding [J]. Transactions on electronics packaging manufacturing, 2003, 26(1): 46~53.

DOI: 10.1109/tepm.2003.812999

Google Scholar

[8] Hu C M, Guo N Qand Ling S F. The vibration characteristics of capillary in wire bonder [C]. In Proceedings of EPTC'98, Singapore , 1998: 202-205.

Google Scholar

[9] Hu C M, Guo N Q, Du H and Xu L M. Dynamic characteristics of stacked piezoelectric transducers of ultrasonic wire bonders used in integrated circuit packaging[J]. Mechanical Engineering Science, 2003, 217(3): 341~352.

DOI: 10.1243/095440603762870009