Feed-Forward Control of Input-Series and Output-Parallel DC Transformer

Article Preview

Abstract:

The input-series and output-parallel (ISOP) DC transformer, which has no output filter, runs under near 100% duty ratio, and is easily achieve zero voltage switching (ZVS) conditions and higher efficiency, is more and more attractive in the high input voltage and high power applications. In order to achieving input voltages sharing in ISOP DC transformer based on two non-resonant DC transformer modules, the feed-forward control method is proposed in this paper. And the principle of the proposed control is analyzed in detail. Finally, experimental results are given to verify the proposed control method to have a good ability of sharing the input voltages.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

791-796

Citation:

Online since:

July 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Yuancheng Ren, Ming Xu, Julu Sun, et al, A family of high power density unregulated bus converters, IEEE Trans. Power Electronics, vol. 20, no. 5, 2005, pp.535-542.

DOI: 10.1109/tpel.2005.854025

Google Scholar

[2] L. Haachitaba Mweene, David M. Otten, Martin F. Schlecht, A high-efficiency 1. 5KW, 390-50V half bridge converter operated at 100% duty-ratio, "APEC , 92 Conference Proceedings, 1992, pp.723-730.

DOI: 10.1109/apec.1992.228341

Google Scholar

[3] José Rodríguez, Jih-Sheng Lai, Fang Zheng Peng, Multilevel inverters: a survey of topologies, controls, and applications, IEEE Transactions on Industrial Electronics, vol. 49, no. 4, 2002, pp.724-738.

DOI: 10.1109/tie.2002.801052

Google Scholar

[4] A. Bhing, N. Mohan, R. Giri, et al, Series-parallel connection of DC-DC converter modules with active sharing of input voltage and load current, IEEE APEC, vol. 2, 2002, pp.648-653.

DOI: 10.1109/apec.2002.989314

Google Scholar

[5] Raja Ayyanar, Ramesh Giri, Ned Mohan, Active input-voltage and load-current sharing in input-series and output-parallel connected modular DC-DC converters using dynamic input-voltage reference scheme, IEEE Transactions on Power Electronics, vol. 19, no. 6, 2004, pp.1462-1473.

DOI: 10.1109/tpel.2004.836671

Google Scholar

[6] Xinbo Ruan, Lulu Cheng, Tao Zhang, Control strategy for input-series output-paralleled converter, Power Electronics Specialists Conference, 2006, pp.1-8.

DOI: 10.1109/pesc.2006.1711769

Google Scholar

[7] Ramesh Giri, ijay Choudhary, Raja Ayyanar, et al, Common-duty-ratio control of input-series connected modular DC-DC converters with active input voltage and load-current sharing, IEEE Transaction on Industry Applications, vol. 42, no. 4, 2006, pp.1101-1111.

DOI: 10.1109/tia.2006.876064

Google Scholar

[8] ZhangXianjin, Chen Jie, Gong Chunying, Research on DC/DC transformer, High Voltage Engineering, vol. 35, no. 5, 2009, pp.1144-1149.

Google Scholar

[9] J. Morren, S. W.H. de Haan, J. A. Ferreira, Design study and scaled experiments for high-power DC-DC conversion for HVDC-systems, Power Electronics Specialists Conference, vol. 3, no. 3, 2001, pp.1529-1534.

DOI: 10.1109/pesc.2001.954336

Google Scholar

[10] ZhangXianjin, Chen Jie, Gong Chunying, Input-series output-paralee DC transformer, Journal of Nanjing University of Aeronautics & Astronautics, vol. 42, no. 2, 2010, pp.30-36.

Google Scholar