A Case Study on Indoor Comfort of Lecture Rooms in University Buildings

Article Preview

Abstract:

The indoor environment of lecture rooms in universities can affect the learning of students. Nevertheless, study on the actual conditions of air in relation to indoor air quality is rare. This paper presents a case study on the indoor comfort of selected lecture rooms in a university. Two rooms of different sizes and ventilation rates were selected, in which the indoors air temperature, CO2 content and relative humidity were measured both when occupied and unoccupied. The study revealed that occupancy by students did not directly affect the relative humidity in the lecture rooms, probably due to the dominating influence of the outdoor air. It was found from the study that under high occupancy, the room temperature and CO2 content would be higher than the recommended level and thus affected the comfort level of students and consequently their learning ability during the lecture.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

821-826

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] A Guide on Indoor Air Quality Certification Scheme for Offices and Public Places, Indoor Air Quality Management Group, The Government of the Hong Kong Special Administrative Region, (2003).

Google Scholar

[2] ASHRAE, ASHRAE Standard 55 - Thermal Environmental Conditions for Human Occupancy, Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, (2004).

Google Scholar

[3] Brooks, B. O. & Davis, W. F., Understanding Indoor Air Quality, London, CRC Press, (1991).

Google Scholar

[4] Sekine, Y. & Watts, S., Indoor Air Standards in Japan for Healthy Environment (Presented at the 7th Indoor Air Quality 2006 Meeting, Braunschweig, November 15, 2006), Available from: http: /iaq. dk/iap/iaq2006/Sekine_IAQ2006. pdf [Accessed 19 January 2010], (2006).

Google Scholar

[5] Mitamura, T., Osawa, H., Kuwasawa, Y. & Miura, H., Survey on Indoor Air Quality in Contemporary Residential Buildings in Japan, In 6th International Conference on Indoor Air Quality, Ventilation & Energy Conservation in Buildings - IAQVEC. Sendai, Japan, (2007).

Google Scholar

[6] DOSH, Code of Practice on Indoor Air Quality. Putrajaya: Department of Occupational Safety and Health Ministry Resources, Ministry of Human Resources, Malaysia, (2005).

Google Scholar

[7] ASHRAE Handbook - Fundamentals - SI Units, Atlanta, American Society of Heating, Refrigerating and Air-Conditioning Engineers, (2005).

Google Scholar

[8] MMD., Malaysian Meteorological Department. Ministry of Science, Technology and Innovation, http: /www. met. gov. my [Accessed 15 September 2009], (2009).

Google Scholar