A Study on IAQ in a Welding Laboratory

Article Preview

Abstract:

ndoor Air Quality (IAQ) has become an important occupational health and safety concern in educational environment at institutions of higher learning. In a survey conducted on a polytechnic in Malaysia, many of the students and lecturers expressed feeling of discomfort and uneasy due to resulting smoke from the welding activities while attending the workshop session. They felt that the room temperature and humidity also contributed to discomfort. Consequently, students had difficulties to concentrate and focus on their learning. The objective of this study was to determine the indoor air quality of a selected welding laboratory in the polytechnic comprising arc and gas welding stations. The important IAQ parameters considered in this study were the dry bulb air temperature, relative humidity, CO2 level and dust particles. Measurements were conducted using commercial IAQ instruments. From the study it was found that the levels of dust particles was higher than the recommended limit at times in the arc welding station. The CO2 level was observed acceptable in both welding stations. On relative humidity, a mixed result was found. Overall, the results implied that the welding laboratory require attention in meeting acceptable Indoor Air Quality.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

947-952

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] U.S. EPA, Why Is the Environment Indoors Important to Us? Indoor Environment Division, U.S. Environmental Protection Agency, Washington DC. (2000).

Google Scholar

[2] Taneja A, Saini R, Masih A., Indoor air quality of houses located in the urban environment of Agra, India. Ann N Y Acad Sci, 1140 (2008), pp.228-245.

DOI: 10.1196/annals.1454.033

Google Scholar

[3] Byeon S., A study on the airborne concentration of welding fumes for some manufacturing industries, Journal of Korean Industrial Hygienists Association. 5(1995), pp.172-183.

Google Scholar

[4] Occupational Safety and Health, Use and Standards of Exposure of Chemicals Hazardous to Health. Malaysia : USECHH. (2000).

Google Scholar

[5] Masey, D et al. (2012).

Google Scholar

[6] Saraga, D et al. (2011).

Google Scholar

[7] Muhamad-darus, F., Zain-ahmed, A., and Talib, M. (2011). Peliminary Assesment of Indoor Air Quality in Terrace Houses. Health and The Environmental Journal, 2, 8-14.

Google Scholar

[8] Tippayawong N. et al., Indoor/outdoor relationships of size resolved particles concentrations in naturally ventilated school environments. Building and Environment. 44(2009), 188-197. Elsevier Ltd. doi: 10. 1016/j. buildenv. 2008. 02. 007.

DOI: 10.1016/j.buildenv.2008.02.007

Google Scholar

[9] ASHRAE, Position Document in Indoor Air Quality. (2010).

Google Scholar

[10] Wijewardane, S., and Jayasinghe, M.T.R. Thermal comfort temperature range for factory workers in warm humid tropical climates, Renewable Energy 33 (2008) 2057–(2063).

DOI: 10.1016/j.renene.2007.11.009

Google Scholar