Study on AC Artificially Pollution Flashover Performance of EHV Class Insulator String of 32 Units

Article Preview

Abstract:

Study on pollution flashover characteristics of EHV system have great reference on engineering.In this paper,the relationship between 50% ac flashover voltage U50 of class insulator string of 32 units and ρESDD, ρNSDD was analyzed based on experimental results. It was shown that the relationship between U50 and ρESDD is the same as the one between U50 and ρNSDD, in which the U50 reduces with the increase of ρESDD by a power function, and the influences of ρESDD and ρNSDD on U50 are mutually independent. By using the least square method, the value of exponent of a and b were determined.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1456-1459

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Ramos N. G, Campillo R.M. T and Naito K., A study on the characteristics of various conductive contaminants accumulated on high voltage insulators, IEEE Transactions on Power Delivery, Vol. 8, n. 4, pp.1842-1850, (1993).

DOI: 10.1109/61.248293

Google Scholar

[2] R. Hackam, Outdoor HV composite polymeric insulators , IEEE Trans. on Dielectrics and Electrical Insulation, Vol. 6, n. 5, 557-585, (1999).

DOI: 10.1109/94.798114

Google Scholar

[3] J. Hu,C. Sun,X. Jiang,Z. Zhang and L. Shu, Flashover performance of pre-contaminated and iced-covered insulators to be used in 1000 kV ac transmission lines, IEEE Transaction on Dielectrics and electrical and insulation, Vol. 14, n. 6, pp.1347-1353, (2007).

DOI: 10.1109/tdei.2007.4401217

Google Scholar

[4] J. Yuan ,X. Jiang, L. Shu,Z. Zhang and Y. Zhang, Influence of Salt/Non-soluble Deposit Density on AC Artificially Pollution Flashover Performance of Various Types Insulators , Proceedings of the CSEE, Vol. 6, n. 2, pp.96-101, 2007(in Chinese).

Google Scholar

[5] X. Jiang,J. Yuan, Z. zhang, J. Hu and C. Sun, Study on ac artificially-contaminated flashover performance of various types of insulators, IEEE Transactions on Power Delivery, Vol. 22, n. 4, pp.2567-2574, (2007).

DOI: 10.1109/tpwrd.2007.899760

Google Scholar

[6] R. Matsuoka, K. Kondo, and K. Natio, Influence of non-soluble contaminants on the flashover voltages of artificially contaminated insulators, IEEE Trans. on Power Delivery, Vol. 11, n. 1, pp.420-4301996.

DOI: 10.1109/61.484042

Google Scholar

[7] IEC60507-1991. Artificial pollution tests on high-voltage insulators to be used on a. c. systems.

Google Scholar