A Novel Power Reserve Operating Scheme of DFIG

Article Preview

Abstract:

The system equivalent rotary inertia and frequency control capability are decreased with growing continuously of wind power penetration, because the doubly fed induction generator (DFIG) is decoupled from system frequency, which will bring a new challenge to the large wind power integration. On the basic of analyzing power-speed characteristic of DFIG which operates at different wind speeds, the de-load operating strategy of DFIG based on coordinated controlling of over-speed and changing pitch was proposed, at the same time the de-load operating curve of DFIG was given through calculating, and the enhancing of kinetic energy was proved by theoretical analysis. And the power reserve capacity of system is enhanced.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

644-647

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] LI Junjun, WU Zhengqiu.Small signal stability analysis of wind power generation participating in primary frequency regulation[J].Proceeding of the CSEE, 2011, 31(13): 1-9.

Google Scholar

[2] CHI Yongning, WANG Weisheng, LIU Yanhua.Impact of large scale wind farm integration on power system transient stability.Automation of Electric Power Systems, 2006, 30(15): 10-14.

Google Scholar

[3] A. Teninge, C. Jecu, D. Roye, S. Bacha, J. Duval, R. Belhomme.Contribution to frequency control through wind turbine inertial energy storage[J].IET Renewable Power Generation, 2009. 3(3): 358-370.

DOI: 10.1049/iet-rpg.2008.0078

Google Scholar

[4] Xinshou TIAN, Yuehui HUANG, Xiaoyan XU, Weisheng WANG.Comparison of the frequency control strategy of wind turbines and its optimization scheme[C].The 2th International Conference on Energy, Environment and Sustainable Development, 2012: 494-499.

Google Scholar

[5] XUE yingcheng, TAI Nengling, SONG Kai, XIONG Ning.Variable-speed wind turbines provide primary reserve for frequency control[J].Electric Power Automation Equipment, 2010, 30(8): 75-80.

Google Scholar

[6] de ALMEIDA R G, PECAS J A.Participation of doubly fed induction wind generators in system frequency regulation[J].IEEE Trans on Power Systems, 2007, 22(3): 944—950.

DOI: 10.1109/tpwrs.2007.901096

Google Scholar

[7] ZHANG Zhaosui, SUN Yuanzhang, LI Guojie, CHENG Lin, LIN Jin.Frequency regulation by doubly fed induction generator wind turbines based on coordinated overspeed control and pitch control[J].Automation of Electric Power Systems, 2011, 35(17): 20-25.

Google Scholar

[8] CAO Zhangjie.Study on control ctrategy of DFIG wind turbine for the participation of system primary frequency regulation[D].Southwest Jiaotong University Master Degree Thesis, 2012.

Google Scholar

[9] Jacob Aho, Andrew Buckspan, Jason Laks etc.A tutorial of wind turbine control for supporting grid frequency through active power control[C].2012 American Control Conference, June 27-June 29, 2012: 3120-3131.

DOI: 10.1109/acc.2012.6315180

Google Scholar

[10] A. Zertek, G. Verbic, M. Pantos.Optimised control approach for frequency-control contribution of variable speed wind turbines[J].IET Renewable Power Generation, 2012, 6(1): 17-23.

DOI: 10.1049/iet-rpg.2010.0233

Google Scholar

[11] Z. -S. Zhang, Y. -Z. Sun, J. Lin, G. -J. Li.Coordinated frequency regulation by doubly fed induction generator-based wind power plants[J].IET Renewable Power Generation, 2012, 6(1): 38-47.

DOI: 10.1049/iet-rpg.2010.0208

Google Scholar

[12] H.T. Ma, B.H. Chowdhury.Working towards frequency regulation with wind plants: combined control approaches[J].IET Renewable Power Generation, 2010, 4(4): 308-316.

DOI: 10.1049/iet-rpg.2009.0100

Google Scholar

[13] CHANG—cHIEN L R, LIN W T, YIN Y C.Enhancing frequency response control by DFIGs in the high wind penetrated power systems[J].IEEE Trans on Power Systems, 2011, 26(2): 710-7l8.

DOI: 10.1109/tpwrs.2010.2052402

Google Scholar

[14] Le-Ren Chang-Chien, Member, IEEE, Ya o-Ching Yin.Strategies for operating wind power in a similar manner ofconventional power plant[J].TRANSACTIONS ON ENERGY CONVERSION, 2009, 24(4): 926-934.

DOI: 10.1109/tec.2009.2026609

Google Scholar