Research on the Application of New Active Inverter Technology in Battery Maintenance

Article Preview

Abstract:

This paper presents a discharge inspection method based on new active inverter feedback discharge after comparison with the check discharge from pure resistance of power station batteries. A new active inverter system has been developed with SPWM pulse width modulation technology, which is based on DC/DC circuitry, along with a three-phase full bridge inverter and control topology circuits. In addition, the principle for selecting the parameters of RCL elements of the system has been analyzed. This paper also presents a detection method combining active detection with passive detection for the islanding effect which exists in the grid-connected discharge system, according to the islanding effect of grid-connected discharge equipment, so as to stably discharge without interference on the grid.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

2077-2084

Citation:

Online since:

October 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] W.Q. Meng: Discussion on the testing method of the VRLA batteries used in electric power systems [J]. Chinese LABAT Man, (2012), 49: pp.27-30, in Chinese.

Google Scholar

[2] W. Dou: Research on the Current Controller of Three Phase Photovoltaic Grid-connected Inverter [J]. Power Electronics (2007), 41(1): pp.85-86, in Chinese.

Google Scholar

[3] J. Dannehl, F.W. Fuchs, S. Hansen: PWM Rectifier with LCL-filter using Different Current Control Structures. IEEE Trans. on Power Electronics and Applications (2007), (9): p.1~10.

DOI: 10.1109/epe.2007.4417531

Google Scholar

[4] M. Liserre, F. Blaabjerg, S. Hansen: Design and Control of An LCL-filter Based Active Rectifier. IEEE Trans on Industry Applications (2001), 38(2): pp.299-307.

DOI: 10.1109/ias.2001.955428

Google Scholar

[5] S.C. Zheng: Study on Control Strategy of Three Phase Photovoltaic Grid-connected System [J]. Electrical Engineering (2007), (3): pp.43-46, in Chinese.

Google Scholar

[6] L. Chen: The Island Effect Simulation Research in the Solar Grid-connected PV System [J] (2009), 33(1): pp.59-62, in Chinese.

Google Scholar

[7] Y.X. Qiao: Study of Islanding Detection of the Grid-Connected Photovoltaic System [J] (2010), (11): pp.23-27, in Chinese.

Google Scholar

[8] H.L. Sun, L.A.C. Lopes: Analysis and Comparison of Islanding Detection Methods Using a New Load Parameter Space[C]. 30th IEEE Industrial Electronics Society Conference, Korea (2004), pp.1172-1177.

DOI: 10.1109/iecon.2004.1431741

Google Scholar

[9] V. John, Z.H. Ye, A. Kolwalker: Investigation of anti-islanding protection of power converter based distributed generators using frequency domain analysis [J]. IEEE Transactions on Power Delivery (2004), 19(5): pp.168-176.

DOI: 10.1109/tpel.2004.833435

Google Scholar