Numerical Studies on R22 Refrigerant Compressor Using Environment Friendly Working Fluids

Article Preview

Abstract:

Vapour compression refrigeration is the most widely used method in domestic and commercial air conditioning and refrigeration systems. R22 (difluoromonochloromethane) is the most widely used HCFC (hydro chlorofluorocarbon) refrigerant in residential, commercial, industrial and transport cooling systems. Montreal protocol in 1987 banned the use of CFCs (chlorofluorocarbon) due to their adverse impact on the environment causing ozone depletion and global warming. HCFCs are also being phased out, though they are less destructive than CFCs. The present work explores compressor performance using alternate environment friendly working fluids so that R22 can be replaced in future. The refrigerants used for the studies are R134a (tetrafluoroethane), R290 (propane) and R600a (isobutane). Compressor performance is analysed by varying refrigerant mass flow rate, evaporator and condenser temperatures and studying their effect on compressor size, power and discharge temperature. A numerical simulation code has been developed in MATLAB using refrigerant properties taken from REFPROP.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

21-26

Citation:

Online since:

January 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] C Aprea , A Greco 2003, Performance evaluation of r 22 and r 407 c in a vapour compression plant with reciprocating compressor, Applied Thermal Engineering, Volume 23, Issue 2, February 2003, Pages 215-227.

DOI: 10.1016/s1359-4311(02)00160-6

Google Scholar

[2] Y. S Lee, C. C Su , 2002, Experimental studies of isobutane (R600a) as the refrigerant in domestic refrigeration system , applied thermal engineering Volume 22, Issue 5, Pages 507–519.

DOI: 10.1016/s1359-4311(01)00106-5

Google Scholar

[3] Neil A Roberts, Owen R Chambers, 2004, Energy saving refrigerant blends comprising R125, R134a, R600 OR R600a.

Google Scholar

[4] James M. Calm, Dr Piotr A. Domanski , 2004, R22 replacement status , ASHRAE Journal, American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), USA, 46(8): 29-39.

Google Scholar

[5] C Aprea, C Renno , March 2004, An analysis of the performances of a vapour compression plant working both as a water chiller and a heat pump using R22 and R417A, Applied Thermal Engineering, Volume 24, Issue 4, , Pages 487–499.

DOI: 10.1016/j.applthermaleng.2003.10.006

Google Scholar

[6] R Cabello , E Torella , September 2004, Experimental evaluation of a vapour compression plant performance using R134a, R407C and R22 as working fluids, Applied Thermal Engineering, Volume 24, Issue 13, Pages 1905–(1917).

DOI: 10.1016/j.applthermaleng.2003.12.003

Google Scholar