Effect of Hydraulic Retention Time on Pollutant Removal Performance of Biological Contact Oxidation Process Treating Hospital Wastewater

Article Preview

Abstract:

A study on hospital wastewater treatment was carried out using biological contact oxidation process. The effect of hydraulic retention time (HRT) on BOD5, CODCr and SS removal was investigated. The results showed that the removal rate of BOD5, and CODCr was ascending with the increase of HRT using the contrast test of five different HRTs. When the HRT was more than 4h, the effluent BOD5, CODCr could meet the discharge standard (GB18466-2005). In considering of raising the biodegradability of effluent, 4h was recommended in this study. However, the whole trend of SS variation of system was not obvious with the increase of HRT, and the effluent SS could not meet the discharge standard (20mg/L). Thus, the additional processing steps to remove SS would be necessary.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

725-729

Citation:

Online since:

January 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] H. Y Ai, Q.H. Wang, W.M. Xie, et al. Water&Wastewater Engineering Vol. 31 (2005), pp.88-92(In Chinese).

Google Scholar

[2] J. Dong. Graduate dissertation for master in Taiyuan University of Technology (2007).

Google Scholar

[3] Sakai Y, Nitta Y, Takahashi F. Water Research Vol. 28 (1994), pp.1175-1179.

Google Scholar

[4] Wijeyekoon S, Mine T, Satoh H, et a1. Water Research Vol. 38 (2004), pp.2479-2488.

Google Scholar

[5] W.B. Wang, G.W. Gu, H.X. Liu. Journal of Environmental Sciences Vol. 23(2003) pp.428-431(In Chinese).

Google Scholar

[6] H. Y Li, Y. Zhang, F. Gao. Environmental Science Vol. 27(2006) pp.1862-1865(In Chinese).

Google Scholar

[7] W.Y. Li, Z.H. Zhao, S.M. Li, et al. China Water&Wastewater Vol. 28(2012) pp.75-77(In Chinese).

Google Scholar

[8] H. B Zhou, Cord-ruwisch Ralf, J. Chen. The Chinese Journal of Process Engineering Vol. 1 (2001) pp.180-184(In Chinese).

Google Scholar

[9] X.M. Peng, L. Lu, W.L. Zhang. Technology of Water Treatment Vol. 35 (2009) pp.88-91(In Chinese).

Google Scholar

[10] L.P. Qiu, J. Ma, L.X. Zhang. Environmental Pollution and Control Vol. 26 (2004) pp.433-436(In Chinese).

Google Scholar

[11] H. L Kong, H.F. Wu. China Biogas Vol. 26(2008) pp.15-18(In Chinese).

Google Scholar

[12] L. Zhang, W.G. Li, D.Y. Zhang, et al. Journal of Natural science of Heilongjiang University Vol. 29 (2012) pp.659-665(In Chinese).

Google Scholar