Performance Test of a 5-Stage Helico-Axial Multiphase Pump

Article Preview

Abstract:

A 5-stage helico-axial multiphase pump was tested for studying its performance. The multiphase pump was tested on the conditions of different speed and different gas volume fraction (GVF). According to the test result, performances of the pump were analyzed. And the effects of speed and GVF to differential pressure and efficiency as well as to power of the pump were analyzed at the same time, so some conclusions were made basing of the above research and some of them are very helpful for the future application on the oilfield.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

399-404

Citation:

Online since:

March 2011

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Mack Shippen, Stuart Scott. Multiphase Pumping as an Alternative to Conventional Separation, Pumping and Compression. the 34th Annual PSIG meeting, Portland, 2002: 1-8.

Google Scholar

[2] J. Falcimaigne, J. Brac, Y. Charron, et al. Multiphase Pumping: Achievements and Perspectives. Oil & Gas Science and Technology, 2002, 57(1): 99-107.

DOI: 10.2516/ogst:2002007

Google Scholar

[3] J. Falcimaigne, P. Durando, M. Loupias et al. Multiphase Rotodynamic Pumps Extend Their Operating Capabilities. European Petroleum Conference-EUROPEC, London, 1994. SPE 28882.

DOI: 10.2118/28882-ms

Google Scholar

[4] H. Saadawi. Operating Multiphase Helicoaxial Pumps in Series to Develop a Satellite Oil Field in a Remote Desert Location. SPE Annual Technical Conference, California, 2007: SPE 109785.

DOI: 10.2118/109785-ms

Google Scholar

[5] Mack Shippen, Stuart Scott. Multiphase Pumping as an Alternative to Conventional Separation, Pumping and Compression. Prepared for Presentation at the 34th Annual PSIG meeting Portland, Oregon. October 25, (2002).

Google Scholar

[6] Li Qingping, XUE Dunsong, LU Wenqiang, Some Discussions about the Design of Rotodynamic Multiphase Pump. Journal of Engineering Thermophysics, 1999, 20(1): 61-64.

Google Scholar

[7] Li Qing-Ping, XUE Dun-Song, ZHU Hong-Wu, etc. Research on Hydraulic Design Concept of an Helico-axial Multiphase Pump and its Experimental Studies on Performances. Journal of Engineering Thermophysics, 2005, 26(1): 84-87.

Google Scholar

[8] Zhu Hongwu, Li Zhongfang, Li Qingping. Discussion on Design Scale of Flow Parameters of Helico-axial Multiphase Pump. Journal of Engineering Thermophysics, 2005, 26(6): 954-956.

Google Scholar

[9] Jinya Zhang, Hongwu Zhu, Chun Yang et al. et al. Multi-objective Shape Optimization of Helico-axial Multiphase Pump Impeller Based on NSGA- II and ANN. Energy Conversion and Management, 2011, 52(1): 538-546.

DOI: 10.1016/j.enconman.2010.07.029

Google Scholar