Firefighting Tactics during a Fire Event at a Textile Factory

Article Preview

Abstract:

Many factories contain chemical substances, raw materials, and finished and semi-finished products; thus, a factory fire can cause substantial property losses and endanger lives. The Fire Dynamics Simulator (FDS) developed by the National Institute of Standards and Technology was used in this study to simulate a fire event at a textile factory in Taiwan. The circumstances of a 2010 fire event in Zhubei City were recreated using data from the fire department and print media, exploring changes in temperature, smoke, and the concentrations of harmful gases (i.e., carbon monoxide; CO). Criteria were established for judging the firefighting techniques used during the fire event. In other words, simulated results of the FDS were used to analyze and assess the planning and use of firefighting tactics to enhance the efficiency of firefighting and rescue techniques, decrease casualties and property losses, and increase the reference value of this study in its application to fighting future factory fires.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

335-341

Citation:

Online since:

February 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Information on http: /www. nfa. gov. tw.

Google Scholar

[2] K. McGrattan, Randall McDermott, Simo Hostikka, Jason Floyd, Fire Dynamics Simulator (Version 5) User's Guide, National Institute of Standards and Technology, (2010).

DOI: 10.6028/nist.sp.1019-5

Google Scholar

[3] S. C. Wang, C. S. Lin, C. C. Yu, Dynamic Simulation of Backdraft Phenomena in a Townhouse Building Fire, Heat Transfer-Asian Research, Vol. 37, No. 3 (2008), pp.153-164.

DOI: 10.1002/htj.20196

Google Scholar

[4] Jen-Hao Chi, Using Fire Dynamics Simulator to Reconstruct a Hydroelectric Power Plant Fire Accident, Journal of Forensic Sciences, Vol. 56, No. 6 (2011).

DOI: 10.1111/j.1556-4029.2011.01887.x

Google Scholar

[5] National Institute of Standards and Technology. Test Type: Cone Calorimeter, Test Number: t5603, Description File: t5603. [Online] (2011).

Google Scholar

[6] Australian government Department of Health and Ageing Office of the Gene Technology Regulator,The Biology of Gossypium hirsutum L. and Gossypiumbar badense L. (cotton).

Google Scholar

[7] Bernard Klaene and Russell Sanders, Structural Firefighting: Strategy and Tactics (2007).

Google Scholar

[8] IFSTA, Essentials of Fire Fighting and Fire Department Operations, 6th ed. (2013).

Google Scholar