Study on Iron Release with Various Blending of Desalinated Water and Tap Water

Article Preview

Abstract:

This study examined effects of various blending ratio of desalinated water and tap water on iron release. Pipe rig tests were conducted to simulate and demonstrate iron release in response to water quality changes. Results show that compare to conventional treated water, desalinated water has a pronounced effect on the iron release in ductile iron pipe; increasing fractions of desalinated water in the blends result in higher total iron release. An increase in pH from 8.0 to 10.0 after 24 hours was found due to alkaline substances (like calcium oxide) releasing from the cement mortar lining and the poor buffering capacity of desalinated water.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

417-426

Citation:

Online since:

February 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Taylor J, Dietz J, Randall A, et al. Impact of RO-desalted water on distribution water qualities[J]. Water Science & Technology, 2005, 51(6-7): 285-291.

DOI: 10.2166/wst.2005.0648

Google Scholar

[2] Cooley H, Gleick P H, Wolff G. Desalination: with a Grain of Salt[J]. Pacific Institute. June, (2006).

Google Scholar

[3] Shi B, Taylor J S. Iron and copper release in drinking-water distribution systems[J]. Journal of environmental health, 2007, 70(2): 29-36, 44, 46.

Google Scholar

[4] Xiao W, Hong S, Tang Z, et al. Effects of blending: on total copper release in distribution systems[J]. Journal-American Water Works Association, 2007, 99(1): 78-88.

DOI: 10.1002/j.1551-8833.2007.tb07848.x

Google Scholar

[5] Lahav O, Salomons E, Ostfeld A. Chemical stability of inline blends of desalinated, surface and ground waters: the need for higher alkalinity values in desalinated water[J]. Desalination, 2009, 239(1): 334-345.

DOI: 10.1016/j.desal.2008.07.006

Google Scholar

[6] Imran S A, Dietz J D, Mutoti G, et al. Red water release in drinking water distribution systems[J]. Journal-American Water Works Association, 2005, 97(9): 93-100.

DOI: 10.1002/j.1551-8833.2005.tb07475.x

Google Scholar

[7] Hao G, YiMei T, Yang L. Study of iron release kinetics model when desalinated water transmitted in water distribution system[C]/Consumer Electronics, Communications and Networks (CECNet), 2011 International Conference on. IEEE, 2011: 1695-1698.

DOI: 10.1109/cecnet.2011.5769179

Google Scholar

[8] P. Sarin et al., Physico-chemical characteristics of corrosion scales in old iron pipes, Water Res., 35(12) (2001) 2961-2969.

DOI: 10.1016/s0043-1354(00)00591-1

Google Scholar

[9] Tang Z, Hong S, Xiao W, et al. Impacts of blending ground, surface, and saline waters on lead release in drinking water distribution systems[J]. Water research, 2006, 40(5): 943-950.

DOI: 10.1016/j.watres.2005.12.028

Google Scholar

[10] Blute N K, McGuire M J, West N, et al. Integration of desalinated seawater into a distribution system: a corrosion pilot study[J]. Journal (American Water Works Association), 2008, 100(9): 117-131.

DOI: 10.1002/j.1551-8833.2008.tb09725.x

Google Scholar

[11] Johansson E L. Importance of water composition for prevention of internal copper and iron corrosion[D]. Chalmers University of Technology, (1989).

Google Scholar

[12] Edwards M, Hidmi L, Gladwell D. Phosphate inhibition of soluble copper corrosion by-product release[J]. Corrosion science, 2002, 44(5): 1057-1071.

DOI: 10.1016/s0010-938x(01)00112-3

Google Scholar

[13] McNeill L S, Edwards M. Review of iron pipe corrosion in drinking water distribution systems[J]. J. AWWA, 2001, 93(7): 88-100.

Google Scholar