Research on Coordination Tuning of V/Hz Limit and Over-Excitation Protection of a Generator

Article Preview

Abstract:

According to the unreasonable phenomenon of coordination of V/Hz limit and over-excitation protection, summarize the coordination principles of V/Hz limit and over-excitation protection with definite time and the principles of V/Hz limit and over excitation protection with inverse time. Analysis the operation characteristics of V/Hz limit and over-excitation protection, and understand two sets of schemes of over-excitation. By learning the relevant theoretical knowledge and their function, it can be derived that V/Hz restriction should take precedence over excitation protection action. On this basis, combined with engineering example to analysis, put forward to consider a reasonable difference to guarantee the safety of generations better when both have a reasonable coordination.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1518-1522

Citation:

Online since:

April 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] DL/T 684-2012. Large generator transformer relay setting calculation guidelines [S].

Google Scholar

[2] GB/T 14285-2006. Relay protection and automatic safety device technical regulations [S].

Google Scholar

[3] Tu Yuanyi. Analysis of malfunction reasons of over-excitation protection of a generator [J]. Huadian Technology, 2010, 32, (7): 26: 30.

Google Scholar

[4] He Guanghua. Over-excitation protection of large generators [J]. Chinese Academic Journal Electronic Publishing magazine.

Google Scholar

[5] Lian Jie. Analysis of malfunction of over-excitation protection of a transformer [J].

Google Scholar

[6] Gu Zhifei. A method of realizing over-excitation protection for microcomputer [J]. Electric Power Automation Equipment, 2012, 32(7): 149-152.

Google Scholar

[7] Liu Qu. Power system stability and generator excitation control[M]. Beijing: China Electric Power Press, (2007).

Google Scholar

[8] Wang Weijian. Principle and application of relay protection of the main electric equipment [M]. Beijing: China Electric Power Press, (2010).

Google Scholar

[9] Beijing sifang following the bartender automation co., LTD. CSC-300 digital set of generator transformer protection device, (2006).

Google Scholar

[10] Zhu Shizhang. Generator excitation system test [M]. Beijing: China Electric Power Press, (2005).

Google Scholar