Experimental Investigation and Numerical Simulation for High Temperature Air Source Heat Pump with New Mixed-Refrigerant

Article Preview

Abstract:

Studies on air source heat pump (ASHP) transfer to high temperature, the performance of air source heat pump greatly depends on the ambient temperature. Aimed at the prototype aeroplane of high temperature air source heat pump, New mixed-refrigerant M-R was adopted, and a simulation was made under a standard conditions with Aspen Plus software. And the results was validated by the experiments. The results showed that a well trend between theory and experiments. In addition, experimental investigation of high temperature air source heat pump were carried out at different conditions. The COP was 1.15, the discharge temperature of compressor was 108.6°Cwhen the outlet water temperature was 85.1°C. The heating capacity is superior. This achieved a leading level at home and abroad.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

752-755

Citation:

Online since:

March 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Wanghuai Xin, Guo Tao, Wang Jixiao. The cycle performance of several working fluid in high temperature heat pump. ACTA ENERGLAE SOLARIS SINICA, 2010, 31 (5) 592-597.

Google Scholar

[2] TX Li, KH Guo, RZ Wang. High temperature hot water heat pump with non-azeotropic refrigerant mixtureHCFC-22/HCFC-141b. Energy Conversion and Management, 43 (2002) 2033-(2040).

DOI: 10.1016/s0196-8904(01)00150-9

Google Scholar

[3] Chen Jianxin, Chen ZS, Wu Peng. Prediction of the latent heat of refrigerant mixtures. Journal of Engineering Thermophysics, 2007, 28 (3) 379-381.

Google Scholar

[4] Zhong Jian. Simulation model for researching and developing the high-temperature heat pump with two-stage centrifugal compressor. Refrigeration and Air-condition, 2010, 10 (4) 18-22.

Google Scholar

[5] Zhao Tianyi, Zhang Jili. Optimization of heat exchanger type for two-stage compression high temperature heat pumps. Heating Ventilating and Air Conditioning, 2007, 37 (5) 68-72.

Google Scholar

[6] Xuwei Rong, DU Kai Thermodynamic calculation and analysis on auto-cascade heat pump system. Cryogenic Engineering, 2009, (5) 31-36.

Google Scholar

[7] Li Tingxun, Kai-Hua Guo, Wang Ruzhu. Mixed refrigerant heat source heat pump computer simulation. Engineering Thermophysics, 2002, 23 (5) 543-546.

Google Scholar

[8] Shengjun, Zhang, Huaixin, Wang, Tao. Guo. Experimental investigation of moderately high temperature water source heat pump with non-azeotropic refrigerant mixtures. Applied Energy 87 (2010) 1554-1561.

DOI: 10.1016/j.apenergy.2009.11.001

Google Scholar

[9] Zan Cheng, Shi Lin. Experimental research on HTR04: a non-ozone depleting refrigerant for moderately temperature heat pump. Journal of engineering thermophysics, 2007, 28 (6) 919-921.

Google Scholar

[10] Gu Xiaogang, Wang Yujun, Lu Tan. The study and experiment on air2source hot2water heat pump under high temperature working condition. Refrigeration and air conditioning, 2007, 7 (5) 47-49.

Google Scholar