Preparation and Numerical Simulation of Ni-SiC Composite Coatings Deposited by Electrodeposition
Abstract:
In order to investigate and predict effects of preparation parameters on wear mass loss of Ni-SiC composite coatings, Ni coatings and Ni-SiC composite coatings were prepared on steel substrates by electrodeposition process. The results showed that the contents of SiC particles increased with density of pulse current and on-duty ratio of pulse current increasing. The predictive curves of wear mass losses predicted by ANN had the similar shapes with the measured curve, and the maximum error was 9.7%. When the current density was between 30 A/dm2 and 50 A/dm2, the wear losses of Ni coatings and Ni-SiC coatings decreased with the increase of current density. SiC particles in a composite coating electrodeposited by ultrasonic parameters were much greater in number and were dispersed homogeneously in the deposit, and the Ni-SiC composite coating exhibited a dense structure.
Info:
Periodical:
Pages:
3707-3710
Citation:
Online since:
March 2014
Keywords:
Price:
Сopyright:
© 2014 Trans Tech Publications Ltd. All Rights Reserved