Flashover Pattern Recognition by HMM Based on Fractal Characteristics of Leakage Current on HV Insulators

Article Preview

Abstract:

With the increase of voltage grade in power transmission system and the aggravation of industrial pollution, flashover of contaminated insulators in HV and UHV system is more and more serious, threatening the security of power transmission severely. The key of improving the security of system is exploring the methods of monitoring and recognizing states of insulator’s surface by some character values. In this paper, multi-characteristic Hidden Markov Model is founded with wavelet and chirplet fractal characteristics of leakage current(LC), through which the flashover patterns are recognized during the developing stages. The results show that fractal characteristics HMM recognized flashover pattern efficiently and successfully, and that is useful to help related stuff to make correct decision and ensure the security of power delivery.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1148-1151

Citation:

Online since:

May 2011

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Zhu Jialiu; Development and Prospects of EHV Power Transmission in China[J]. High Voltage Engineering. 1989, 16(1): 69-76.

Google Scholar

[2] SUDA T1 Frequency Characteristics of Leakage Current Wave forms of an Artificially Polluted Suspension Insulator[J] IEEE Transactions on Dielectrics and Electrical Insulation, 2001, 8(4): 705 – 710.

DOI: 10.1109/94.946726

Google Scholar

[3] Litao Wang, Mostafa G. Mehrabi, Elijah Kannatey-Asibu, Jr. Hidden Markov Model-based Tool Wear Monitoring in Turning[J]. Journal of Manufacturing Science and Engineering, 124, 2002: 651—658.

DOI: 10.1115/1.1475320

Google Scholar

[4] Rabiner L R. A tutorial on Hidden Markov Models and selected application in speech recognition[J]. Proceedings of the IEEE, 1989, 77(2): 257-286.

DOI: 10.1109/5.18626

Google Scholar

[5] CHEN Guoyi. Cause Analysis of Fog-flash-over & Wet-flash-over Phenomenon[J]. Central China Electric Power. 2002, 2(15): 21-24.

Google Scholar

[6] Hui Ali, Lin Hui. Chirplet-Fractal Characteristics of Leakage Current on HV Insulators[C]. 2010 International Colloquium on Computing, Communication, Control, and Management (CCCM 2010). Yangzhou, Aug. 20-22 (2010).

DOI: 10.1109/iccasm.2010.5622772

Google Scholar

[7] Hui Ali, Lin Hui. Fractal Characteristics of Leakage Current on HV Insulators[J]. High Voltage Engineering. 2008, 34(6): 1271-1276.

DOI: 10.1109/drpt.2008.4523502

Google Scholar