Dynamic Analysis Subject to Displacement Harmonic Excitation of Liquid Storage Tank with 20000m3

Article Preview

Abstract:

The isolation storage tank with 20000m3 responded to seismic is calculated by using the finite element analysis (FEA) program ANSYS, and horizontal displacement harmonic excitation is considered for investigation of the relative displacement of tank wall, liquid sloshing wave height, and the stress of tank wall. The analysis show that, with isolation, the maximal relative displacement, the maximal liquid sloshing wave height, and the maximal stress of tank wall are reduced obviously compared with tank that without isolation, and as site become soft, the maximal relative displacement of the tank wall at the top and the maximal wave height increase gradually, but the maximal stress of tank wall change little.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

47-50

Citation:

Online since:

June 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] SUN Jiang-ang, ZHANG Li, YUAN Zhao-qing. Dynamic characteristic analysis of base isolation for vertical storage tank[J]. EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2001, 21(3): 140-144(In Chinese).

Google Scholar

[2] GONG Keqin, LIU yang, SUN Jiangang. Influence analysis of damping on the dynamic response of oil storage tank[J]. OIL-GASFIELD SURFACE ENGINEERING, 2006, 12(25): 5-6(In Chinese).

Google Scholar

[3] Yang Xudong, Zhang Shilian. Structure Damper Analysis In Structure Transient Response With Finite Element Method[J]. China Offshore Platform, 2004, 2(19): 30-34(In Chinese).

Google Scholar

[4] GB 50011-2010, Code for Seismic Design of Building[S](In Chinese).