Deduction of Coordinate Transform for Instantaneous Reactive Power Theory

Article Preview

Abstract:

By means of building up a three-dimension coordinate system in vector space, the coordinate transform used in instantaneous reactive power theory (IRPT) proposed by H. Akagi is deduced and through spatial coordinate transform two equivalent three-dimension coordinate systems are obtained. After rigorous mathematical deduction the transformation factor for above-mentioned three-dimension coordinate systems is achieved, thus the coefficient deduction for IRPT is solved and the zero-sequence quantity expressing three-phase asymmetrical system is directly obtained. By use of the theory of rotating phasor, the basic principle of instantaneous spatial vector detection method based on IRPT is explained. The authors’ analysis is available for understanding and improvement of this harmonic current detection method.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1219-1222

Citation:

Online since:

September 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Hirofumi A,Yoshihira K,Akira N.Instantaneous reactive power compensators comprising switching devices without energy storagecomponents[J].IEEE Trans on Industry Applications, 1984,20(3): 625-630.

DOI: 10.1109/tia.1984.4504460

Google Scholar

[2] You Xiaojie,Li Yongdong,Hao Ruixiang,et al.The control of parallel active power filter under un-perfect source voltage [J].Proceedings of the CSEE,2004,24(2):55-60. (in Chinese).

Google Scholar

[3] Zhuo Fang,Pei Yunqing,Zhou Xin,et a1.Application of active power filter in decreasing harmonics in phase-controlled power source[J].Power System Technology,2004,28(2):40-42. (in Chinese).

Google Scholar

[4] Li Zhanying,Ren Zhen,Yang Zemin.Survey on active power system devices and their application study[J].Power System Technology,2004,28(22):40-43. (in Chinese).

Google Scholar

[5] Batard C,Machmoum M,Alvarez F,et al.Control of shunt active power filter for railway sub-station[J].IEEE Industrial Electronics,2006,(11):2511-2516.

DOI: 10.1109/iecon.2006.347585

Google Scholar

[6] X Lu, JM Guerrero, K Sun, JC Vasquez, R Teodorescu, L Huang. Hierarchical control of parallel AC-DC converter interfaces for hybrid micro grids. Smart Grid, IEEE Transactions on 5 (2), 683-692.

DOI: 10.1109/tsg.2013.2272327

Google Scholar

[7] X Lu, JM Guerrero, K Sun, JC Vasquez. An improved droop control method for DC micro grids based on low bandwidth communication with DC bus voltage restoration and enhanced current sharing accuracy. Power Electronics, IEEE Transactions on 29 (4), 1800-1812.

DOI: 10.1109/tpel.2013.2266419

Google Scholar

[8] X Lu, K Sun, JM Guerrero, JC Vasquez, L Huang. State-of-Charge Balance Using Adaptive Droop Control for Distributed Energy Storage Systems in DC Micro-Grid Applications. Industrial Electronics, IEEE Transactions on 61 (6), 2804-2815.

DOI: 10.1109/tie.2013.2279374

Google Scholar