Study Regarding the Determination of Specific Flows of Wastewater for Urban Areas in Romania

Article Preview

Abstract:

IIn 2007, through the accession of Romania to the European Union, the Government of Romania made the commitment to put into practice the project on implementing the Directive 91/271/EEC concerning urban wastewater treatment. For the second transition phase, according to Directive 91/271/EEC, it is necessary that by December 31st, 2015 all the localities with over 10,000 inhabitants should be connected to sewage systems containing treatment plants [1].In order for the Government of Romania to comply with its commitment made at the moment of the accession to the European Union, respectively that all the localities with over 10,000 inhabitants should be connected to treatment plants by the end of 2015, it absolutely necessary to concentrate its efforts for the identification of the optimal methods of household wastewater treatment in terms of investment and operating costs for the urban areas.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

476-485

Citation:

Online since:

October 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Romanian Government, Plan of completion of the 91/271/CEE Directive on the treatment of urban wastewater, Bucharest, 2004, pp.1-39.

Google Scholar

[2] National Administration Romanian Waters", Summary of water quality in Romania in 2013, Bucharest, 2014, 46 pp. Information on: http: /www. rowater. ro/Lists/Sinteza%20de%20calitate%20a%20apelor/DispForm. aspx, ID=13&Source=http%3A%2F%2Fwww. rowater. ro%2FLists%2FSinteza%2520de%2520calitate%2520a%2520apelor%2FAllItems. aspx.

Google Scholar

[3] Standards Association of Romania, Design specifications external sewers, Part 1: Determination of wastewater sewage flows RS 1846-1, Bucharest, 2006, 9 pp. Information on: http: /www. scribd. com/doc/115879698/52785268-stas-1846-1-din-2006-pdf.

Google Scholar

[4] Standards Association of Romania, Water Suply, Quantitative determination of drinking water for urban and rural areas, RS 1343-1, Bucharest, 2006, 20 pp. Information on: http: /users. utcluj. ro/~andreib/Gospodarirea%20apei/Documente/Bibliografie/SR%201343%5B1%5D. pdf.

Google Scholar

[5] T. Schuetze, V. Santiago-Fandino, Quantitative Assessment of Water Use Efficiency in Urban and Domestiv Buildings, Water Journal, 5 (2013) 1172-1193.

DOI: 10.3390/w5031172

Google Scholar

[6] Information on www. planning. org. au/policy/water-and-planning.

Google Scholar

[7] Information on www. pub. gov. sg/conserve/Pages/default. aspx.

Google Scholar