Experimental Study on the Effect of Pinch Parameters and Fluid Viscosity to Flow in Closed Loop Impedance Pump

Article Preview

Abstract:

This paper aims to analyse the performance of impedance pump that uses energy mismatch to drive fluid flow. The experimental setup mainly focus to establish the relationship between the fluids flow rates in elastic tube section connected between two ends of solid tube and pinch mechanism location as well as fluid viscosity. Measurement of fluid flow rate or representation of its velocities resulting from the pumping mechanism is measured using two different supply voltage and constant pincher width. These measured parameters resulting from the pinch mechanism of the elastic tube section were varied at different pinch location along its x-axis direction; divided into two main cases namely (1) 2 V and (2) 3 V at 40 mm to 140 mm pinch location. From the voltage variation, it is found that the maximum flow rate given by voltage 3.0 V at pinch location 40 mm while for the effect of viscosity, the highest flow rate is 93 ml/min. The profiles obtained revealed the characteristic of valve less pump to be the new model of new Ventricular Assist Device use in cardiac patient as well as further explanation about the factor that influence the characteristic of elastic tube.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

932-936

Citation:

Online since:

October 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] G. Liebau, U¨ ber ein ventilloses pumpprinzip, Naturwissenschaften 41 (1954) 327.

DOI: 10.1007/bf00644490

Google Scholar

[2] Forouhar, A. Hickerson, A. Liebling, M. Fraser, S. Dichkinson, and M. Gharib, Personal communication: The embryonic Zebrafish Heart as an Impedance Pump (2015) 10-17.

Google Scholar

[3] Y. Chusri, P. Diloksumpan, and P. Naiyanetr, Current Left Ventricular Assist Device, BMEiCON 9 (2013) 21, 56.

DOI: 10.1109/bmeicon.2013.6687730

Google Scholar

[4] H. Thomann , Z. Angew, A simple pumping mechanism in a valveless tube, J. of applied mathematics and physics. 29 (1978) 169–177.

DOI: 10.1007/bf01601511

Google Scholar

[5] E. Jung, C. Peskin, 2-D simulations of valveless pumping using immersed boundary methods, SIAM J Sci Comput. 23 (2001) 19–45.

DOI: 10.1137/s1064827500366094

Google Scholar

[6] J. Ottesen, Valveless pumping in a fluid-filled closed elastic tube-system: one-dimensional theory with experimental validation, J Math Biol (2003) 309–332.

DOI: 10.1007/s00285-002-0179-1

Google Scholar

[7] A. Borzi , G. Propst, Numerical investigation of the Liebau phenomenon. Z Angew Math Phys. 54 (2003)1050–1072.

Google Scholar

[8] M. Massoudi, J. Kim, and J.F. Antaki, Modelling and Numerical Simulation of Blood flow using the Theory of Interacting Continua, (2013) 56.

Google Scholar

[9] Deborah J. Kozik and Mark D. Plunkett, Mechanical Circulatory Support, Organogenesis. 7 (2012) 6.

Google Scholar

[10] R. Moshe and A. Idit, Net flow rate generation by a multi pincher impedance pump, Computer and fluid 39 (2010) 1634-164.

DOI: 10.1016/j.compfluid.2010.05.016

Google Scholar

[11] M. Mazwan Mahat, M. Arif Sulaiman, Chee Sheng Ow, Rosnadiah Bahsan, N. Merlisa Ali, C.S. Fizi, Impedance Induce Valve Pump in Closed Loop System, Applied Mechanics and Materials (2013), 393, 747.

DOI: 10.4028/www.scientific.net/amm.393.747

Google Scholar