Application Analysis of Expanded Conductor in 1000kV UHV Double-Circuit Line

Article Preview

Abstract:

This paper discusses the feasibility and effectiveness of the application of expanded conduct in 1000kVultra high voltage AC (UHVAC) transmission line. Through the comparison and analysis between expanded conduct and conventional conduct in transmission capacity, mechanical properties, project investment, annual cost and other aspects, it shows that the initial investment of expanded conduct is 4% lower than that of conventional conduct; and the annual cost of expended conductor is superior to that of conventional conduct when transmission capacity, power price and use hours are low.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

318-325

Citation:

Online since:

October 2014

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] China Power Engineering Consulting Group Corporation, etc. The Second Special Report on Preliminary Design of Huainan-Southern Anhui-Northern Zhejiang-Western Shanghai 1000kV AC Line Project – Selection of Conductor and Ground Wire [R], Beijing: State Grid Corporation of China, (2011).

Google Scholar

[2] China Power Engineering Consulting Group Corporation, etc. The First Special Report on Preliminary Design of 1000kV Ximeng-Nanjing UHV AC Transmission Line Project – Selection of Conductor and Ground Wire and Application Research on New Conductor [R], Beijing: State Grid Corporation of China, (2011).

Google Scholar

[3] State Power Economic Research Institute, etc. The Second Special Report on Preliminary Design of Huainan - Nanjing - Shanghai UHV AC Project – Selection of Conductor and Ground Wire and Application Research on New Conductor [R], Beijing: State Grid Corporation of China, (2012).

Google Scholar

[4] State Power Economic Research Institute, etc. The Second Special Report on Preliminary Design of Northern Zhejiang-Fuzhou UHV AC Transmission and Transformation Project – Selection of Conductor and Ground Wire and Application Research on New Conductor [R], Beijing: State Grid Corporation of China, (2013).

Google Scholar

[5] Bencui Liu, Xinqiang Yu, Ricai Guo, et al. Application Prospect of Diameter-extended Conductor in EHV AC Large-capacity Transmission Projects [J]. Power System Technology. November, 2007, 31 (21): 1~10.

Google Scholar

[6] Luqi Zhang, Yang Hao, Xiaoting Li, et al. Application of Diameter-extended Conductor in UHV AC Transmission Line Projects [J]. Electric Power Construction. August, 2012, 33(8): 92~95.

Google Scholar

[7] Jiancheng Wan, Zhen Liu, Baodong Sun, et al. Classification and Applicability of Diameter-expanded Conductor [J]. Electric Power Construction. June, 2010, 31(6): 113~118.

Google Scholar

[8] GB50545-2010. Design Specification of 110kV~750kV Overhead Transmission Line [S]. Beijing: China Planning Press, (2010).

Google Scholar

[9] GB50665-2011. Design Specification of 1000kV Overhead Transmission Line [S]. Beijing: China Planning Press, (2011).

Google Scholar

[10] Ministry of Power Industry. Provisional Regulations of Electric Power Engineering Economic Analysis. February, (1982).

Google Scholar

[11] Shuda Bi. Analysis on Causes of Strand Jumping of Extended Diameter Conductor for 750 kV Transmission Line. Electric Power Construction. September, 2006. 27(9): 1~3.

Google Scholar

[12] Yuchang Feng, Yunge Li, Lianbiao Dun, et al. Operation Summary of the 750kV Oversized Conductor [J]. Electric Power Construction. October, 2007, 28(10): 43~46.

Google Scholar