The Development of Device for On-Line Monitoring Circulating Cooling Water Stability

Article Preview

Abstract:

China is a country lacking of freshwater. With the water pollution from bad to worse, saving water become a serious matter which needs to be settled at once. In order to ensure the system working safely and the water quality, most power plants enable the circle cooling water to work in the low consistence, need more drainage and complement water which will make large waste of water. The good water quantity means that the water doesn’t make the furring and make cautery to the equipment. So we can improve the concentrated multiples of the cycle cooling water to save the water. Based on the specialty of the water used in the power plants, this subject study how to estimate the stability, doing the instrument and watching the stability degree, providing the scientific basis for disposing the circling water. After lots of experiments, we use the stability index as the estimation and use the pH determination as the alkalinity determination.The instrument uses the date collecting card to collect and use computer to dispose the date and control the instrument. The system inspects the stability of the cycle cooling water real time automatically.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1743-1747

Citation:

Online since:

October 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Sun M J, Cheng M, Wang X Q, et al. Study on Monitoring Water Quality Stability of Cycle Cooling Water by Stability Index in Power Plant[C]/Proceedings of the 2011 International Conference on Informatics, Cybernetics, and Computer Engineering (ICCE2011) November 19–20, 2011, Melbourne, Australia. Springer Berlin Heidelberg, 2012: 755-762.

DOI: 10.1007/978-3-642-25194-8_88

Google Scholar

[2] Sun M J, Yang W J, Zhang T, et al. Application of Automatic Temperature Electric Heating Technology in the Fouling Resistance On-Line Monitoring[C]/Proceedings of the 2011 International Conference on Informatics, Cybernetics, and Computer Engineering (ICCE2011) November 19–20, 2011, Melbourne, Australia. Springer Berlin Heidelberg, 2012: 779-785.

DOI: 10.1007/978-3-642-25194-8_91

Google Scholar

[3] 2006 DL T. power plants vapor analysis methods [S] [D].

Google Scholar

[4] ZHANG Guang-wen, SUN ink Jie Xi Lijuan, such as optimization and analysis of the stability index measurements related conditions [J] Tohoku Electric Power University, 2011 (6): 40-42.

Google Scholar

[5] ZHANG Guang-wen, the stability of the circulating water line monitoring ink Sun Jie power plant feasibility study [J] Thermal Power Generation, 2010, 39 (11): 62-64.

Google Scholar