Design and Implementation of Processing Software for D-Peak Changed Pulse Wave

Article Preview

Abstract:

The pulse wave is a very useful physiological signal which can reveal the information of human organs. D-peak change is an important change of pulse. To study the spectrum of the D-peak changed pulse wave quantitatively and get the statistics result of such kind of change, a new algorithm was proposed and a kind of processing software was designed and implemented. The software was tested by more than 200 person-times PPG pulse waves and showed good performance.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1101-1104

Citation:

Online since:

November 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Mahomed FA: The physiology and clinical use of the sphygmograph. Med Times Gazette. Vol. 62( 1872).

Google Scholar

[2] Harvey W. de Motu Cordis, et al, in: Sanguinis in Animalibus 1628. William Fitzer Frankfurt. Translated by KJ Franklin. Oxford, Blackwell (1957).

Google Scholar

[3] Pulse wave is the waveform of pulse travelling in blood vessel, and past studies have showed pulse wave mainly contains the important physiological information of heart and blood vessel [20-22]. ] Bright R, in: Reports of medical cases selected with a view of illustrating the symptoms and cure of diseases by a reference to morbid anatomy. London, Longmans (1827).

Google Scholar

[4] London G. M., Guerin A. P: Influence of arterial pulse and reflected waves on blood pressure and cardiac function. American heart journal. Vol. 138 (1999), p.220-p.224.

DOI: 10.1016/s0002-8703(99)70313-3

Google Scholar

[5] Chun T Lee, et al: Analysis of human pulse wave. IEEE Trans Biomed Engineering. Vol. 30(1983), p.348.

Google Scholar

[6] SU Zi-mei, GUO Jian-ying, LIU Jin: Spectrum feature extraction and automatic recognition of pulse waves. Nanotechnology and Precision Engineering. Vol. 8(2010), p.70-p.74.

Google Scholar

[7] Wang WK, Wang Lin YY, Hsu TL, et al: The relation between meridian and energy distribution from the plus study. Proc 1st International Conference on Bioenergetic Med. (1989), p.302-p.319.

Google Scholar

[8] Young SO, Wang WK, Chang LS, et al: The filter properties of the arterial beds of organs in rats. Acta Physiol Scand. Vol. 145 (1992), p.401.

Google Scholar

[9] Luo Kan, Zhou Qi, Li Ersong, et al: Development DSP pulse wave test instrument. ELECT RONIC MEASUREMENT TECHNOLOGY. Vol. 33 (2010), p.102-p.108.

Google Scholar

[10] QI Bei-bei, WU Xiao-ming, HUANG Yue-shan: The real-time pulse wave signal processing based on MATLAB. Microcomputer Information. Vol. 25(2009), p.184-p.185, p.93.

Google Scholar

[11] Wang Liuyi, Wu Shulun, in: None-traumatic cardiovascular diagnosis technology. Beijing, China Medical Science Press (1996).

Google Scholar