Ultrasonic Testing Numerical Simulation of Austenitic Stainless Steel Pipeline Welding Cladding

Article Preview

Abstract:

In the paper, ultrasonic testing of austenitic stainless steel pipeline welding cladding is stimulated based on ultrasonic testing software CIVA. The result shows that the frequency is higher; the sensitivity on small defect testing is higher. When cylindrical defect with length of 6mm and diameter of 2mm is detected, the frequency is higher, the tested length-section result is more accurate, and the width-section (i.e., diameter) is not affected. The optimum frequency scope for testing the defect should be between 5MHz and 10MHz.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

878-881

Citation:

Online since:

November 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] L. Hemery, P. Calmon and S. Chatillon: Ultrasonics Vol. 40 (2002), p.231.

Google Scholar

[2] A. Bostrom and P. Bovik: International Journal of Solids and Structures Vol. 40 (2003), p.3493.

Google Scholar

[3] X. Zhao, T. Gang, C. Xu: Journal of Nondestructive Evaluation Vol. 29 (2010), p.105.

Google Scholar

[4] M. Spies: NDT&E International Vol. 33 (2000), p.155.

Google Scholar

[5] H.J. Kim, S. J. Song and L.W. Schmerr: Ultrasonics Vol. 44 (2006), p.969.

Google Scholar