Tensile Strength Test of Photo Biocomposites for Application in Biomedical Materials

Article Preview

Abstract:

The aim of this research is to perform the tensile strength of photo biocomposite materials. This material consist of hydroxyapatite (HA) as a filler, tri [ethylene glycol] dimethacrilate as a matrix, shellac as a coupling agent and camphorquinone as a photoinitiator. Four ingredients then were used to two mixtures. The first mixture was mixing of TEGDMA and camphorquinone and the second was shellac coated HA. Two of mixtures were mixed to be one solution and was stirred in magnetic stirrer for 1 hour. The solution then was poured into the mold of tensile strength (10 x 10 x 3 mm) and was activated with visible blue light 410 – 500 nm for 40 seconds in order to be polimerization processes. The irradiation process was done with a maximum thickness 1 mm so that the irradiation process was done 3 times (layer by layer processing). The results of tensile strength test showed that the tensile strength would decrease with the addition of HA or would increase by the addition of TEGDMA. The highest tensile strength was obtained at HA/TEGDMA ratio of 20/80%. This material could be used as a bone substitute materials.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

411-415

Citation:

Online since:

November 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Suchanek and Yoshimura, Processing and properties of hydroxyapatyte based biomaterial for use of hard tissue replacement implant, Journal of Material Research. 13(1) (1998) 94 - 115.

Google Scholar

[2] Nath Shekhar, Subhadip Bodhak, Bikramjit Basu, HDPE-Al2O3-HAp Composites for biomecical applications: processing and characterization, Journal of Biomedical Materials Research Part B Applied Materials (2008).

DOI: 10.1002/jbm.b.31050

Google Scholar

[3] Roeder Ryan K, Michael M Sproul, Charles H Turner, Hydroxyapatite whiskers provide improved mechanical poperties reinforced polymer composites, JOM, 60( 3), (2008) 38-45.

Google Scholar

[4] Tontowi Alva Edy, Diametral tensile strength and microstructure of hydroxyapatyte- photopolymer composite, Journal of Media Teknik no. 4 (2008).

Google Scholar

[5] Osman-Tolga Harorh, Yusuf-Ziya Bayındır, Zuhal Altunkaynak, Abdulgani Tatar, Cytotoxic effect of TEGDMA on THP-1 cell in vitro, Journal Section Oral Medicine and Pathology Bucal (2009).

Google Scholar

[6] Sarkar D, Chu M.C. and Cho S.J. Ceramic-Polymer nanocomposite: alternative choice of bone, Journal of The Korean Ceramic Society. 45(6) (2008) 309-319.

DOI: 10.4191/kcers.2008.45.6.309

Google Scholar

[7] Islas-Blancas ME, Cervantes-Uc JM, Vargas-Coronado R, Cauich-Rodriguez J, Vera-Graziano R, Martinez-Richa A, Characterization of bone cements prepared with functionalized methacrylates and hydroxyapatite. J Biomater Sci Polym (2001) 893-910.

DOI: 10.1163/156856201753113088

Google Scholar

[8] Canul-Chuil A, Vargas-Coronado R, Cauich-Rodriguez J, Martinez-Richa A, Fernandez E, Nazhat SN. Comparative study of bone cement prepared with either HA or α-TCP and functionalized methacrylates, . J Biomater Sci Polym (2003) 55-60.

DOI: 10.1002/jbm.b.10486

Google Scholar

[9] Morejon Lizette, Alonso Eduardo Mendizabal, Jose Angel Delgado Garcia-Menocal, Maria Pau Ginebra, Conrado Aparicio, Francisco Javier Gil Mur, Static Mechanical properties of hydroxyapatite (HA) powder-filled acrilic bone cement: Effect of Type of HA Powder, Published online in WileyScience (2004).

DOI: 10.1002/jbm.b.30166

Google Scholar

[10] Nielsen LE, Landel RF, Mechanical properties of polymers and composites, 2nd ed. New York: Marcel Dekker; (1993).

Google Scholar