The Cause Detection and Analysis of the Surface Cracks on ETIRS

Article Preview

Abstract:

The cause detection and analysis have been made over the surface cracks of external thermal insulating rendering systems made of mortar with bonding powder and using expanded polystyrene granule as aggregate (ETIRS) by means of integrating the basic concept of the cracks and actual project practices, on the basis of structure design, materials performances and construction. The result shows that the major causes for surface cracks, the hazardous ones are caused by poor construction quality. In order to guarantee the quality of external thermal insulation wall, the structure design of the said thermal insulation system shall be underlined and building quality on the key parts, stressed.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

4533-4539

Citation:

Online since:

July 2011

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2011 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] The Construction Quality Acceptance Criterion In Construction Of Energy Saving Projects (GB 50411-2007). Beijing: China Construction Industrial Press, 2007, in chinese.

Google Scholar

[2] External Thermal Insulating Rendering Systems Made Of Mortar with Bonding Powder and Using Expanded Polystyrene Granule as Aggregate (JB 158-2004). Beijing: China Construction Industrial Press, 2004, in chinese.

Google Scholar

[3] Wang Tiemeng. Engineering Structure Cracks Control [M]. Beijing: China Construction Industrial Press, 2008, in chinese.

Google Scholar

[4] Technical Criterion of External Wall Insulation (JG 144-2004). Beijing: China Construction Industrial Press, 2004, in chinese.

Google Scholar

[5] Technical Detection Criterion of Construction of External Wall Insulation System (DGJ32/TJ 58-2010). Nanjing: Construction Dept of Jiangsu Province, 2010 , in chinese.

Google Scholar

[6] Li Shoutian, Tian Ling. The Cause and Elimination of the Cracks on the Aerated Concrete Blocks Infilled Wall [J], Anhui Construction, 2000 (3): 89, in chinese.

Google Scholar

[7] Wang Peizhong, Quality Analysis and Treatment of Aerated Concrete Blocks Mortar Finishing [J], Industrial Construction, 1997 (10); 56~57, in chinese.

Google Scholar

[8] Li Min, Li Huimin, Bai Fengchun. The Study of Elimination of Cracks on Aerated Concrete Blocks Mortar Finishing [J], Low Temperature Construction Technology, 1996 (2): 47~48.

Google Scholar

[9] Fei Huihui, Duankai. The Spot Inspection Method and Its Influence Factors of Energy Saving Construction [J], Construction Technology, 2000 (7): 31~33, in chinese.

Google Scholar

[10] Wang Dejian, the Cause Analysis and Anti-Seepage of External Insulation Wall Seepage [J], Engineering Quality, 2007(8): 18~20, in chinese.

Google Scholar

[11] Fang Denglin. The Cause and Control of the Cracks on External Wall Insulation Layer Surface [J], Low Temperature Construction Technology, 2006 (2): 132~133, in chinese.

Google Scholar

[12] Zhao Xin, Song Xiuying, Wang Dong. The Analysis of the Cracks on External Wall Insulation Surface [J], Journal of Liaoning Professional Agricultural Technology Institute, 2008. 10 (6): 37~38, in chinese.

Google Scholar