Micro-Grid Power Quality Management

Article Preview

Abstract:

As distribute power generation and micro-grid technology develops, more and more researchers attach importance to the problems of power quality in micro-grid, especially the problem of harmonic. This paper describes the impact and harm harmonic has on the power quality of the power grid. It introduces a revised method of managing micro-grid harmonics which uses an active power filter (APF), and the control method of APF is different from the traditional one. It also establishes the simulation model of micro-grid, analyze the simulation results and experiment in actual micro-grid to verify the effectiveness of the proposed method.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1335-1342

Citation:

Online since:

January 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Huang Dongqi, Ai Qi. Yuan Siyuan. Survey on Power Quality Issue of the Connection of New Distributed Energy Power Generation to Grid [J]. Modern Architecture Electric, 2011, 24(12): 1-5.

Google Scholar

[2] Wei Bin, Liu Haiying, Jiao Li, Wang Yulu, Hao Xiwei. Probe into the Current State of Electric Power Quality Management [J]. Shaanxi Electric Power, 2009, (3): 51-54.

Google Scholar

[3] Yan Wenqing. The Research of Micro-grid Power Quality and Harmonic Suppression Technology [D]. Hunan: Central South University, (2012).

Google Scholar

[4] Jiang Ping, Zhao Jianfeng, Tang Guoqing. Power quality problems and control methods [J]. Jiangsu Electrical Engineering, 2003, 22 (1): 16-18.

Google Scholar

[5] Luo An. The Harmonic Elimination and Reactive Power Compensation Technology and Equipment [M]. Beijing: Chinese Power Press, 2006: 4.

Google Scholar

[6] Zhuo Fang, Wang Zhaoan. Development and application of APF [J]. Marine Electric & Electronics Technology, 2000(4): 23-26.

Google Scholar

[7] EI-Habrouk M, Darwish M K, Mehta P. Active Power Filter: a Review [J]. IEE Proceeding-Electric Power Application, 2000, 147(5):403-413.

DOI: 10.1049/ip-epa:20000522

Google Scholar

[8] Li Yan, HouXiumei, Li Bing. Software and hardware design for hybrid active power filter based on DSP [J]. Chinese Journal of Power Sources, 2011, 35(1): 91-93.

Google Scholar

[9] Chen Zhong. The practical key technology research of shunt active power filters [D]. Zhejiang: Zhejiang University, (2005).

Google Scholar

[10] Li Hanshan, Ren Yongfeng, Wang Jianliang, Huang Liang. The simulation model of shunt active power filter (APF) [J]. Control Engineering of China, 2003, 10(6): 564-567.

Google Scholar

[11] Dixon J, del Valle, Y, Orchard M, et al. A Full Compensating System for General Loads, Based on a Combination of Thyristor Binary Compensator, and a PWM-IGBT Active Power Filter [J]. IEEE Trans on Industrial Electronics,2003, 50(5): 982-989.

DOI: 10.1109/tie.2003.817604

Google Scholar

[12] Green T C, Mark J H. Control techniques for active power filters [J]. IEE Proc. -Electr. Power Appl, 2005, 152(2): 369-381.

DOI: 10.1049/ip-epa:20040759

Google Scholar

[13] Vasco Soares, Pedro Verdelho, Gil D. Marques. An instantaneous active and reactive current component method for active filters. IEEE Transactions on Power Electronics, 2000, 15(4): 569-660.

DOI: 10.1109/63.849036

Google Scholar

[14] Conroy, E, Power monitoring and harmonic problems in the modern building [J]. IEEE Power Engineering Journal, Vol. 15, No. 2. 101-107, April. (2001).

DOI: 10.1049/pe:20010207

Google Scholar