Acceleration Response and Serviceability Performance of a 51-Story Building during Typhoon Aere

Article Preview

Abstract:

The Shin Kong Tower located in Taipei City has a height of 244.15 m. It was the tallest building in northern Taiwan when it was built in 1993. This super tall building is susceptible to severe vibrations induced by strong winds. The safety of building structures and contents as well as the comfort of occupants under such strong forces as typhoons remain a major engineering concern. In order to improve our understanding of building structural responses, records of a structural array in the 51-story SK Building in Taipei from the Typhoon Aere are analyzed. In addition, wind data measured at the Taipei Meteorological Station are also used. As a result, the measured data during Typhoon Aere show that the standard deviation of acceleration response at top of the SK Building increases with a power of 2.275 of the wind speed in the longitudinal direction, and a power of 2.302 of the wind speed in transverse direction. It is also observed that the acceleration responses in the transverse direction were generally larger than those in the longitudinal direction during the typhoon. This is mainly due to greater stiffness of the building in the longitudinal direction than the transverse direction. Furthermore, the field measurement data clearly demonstrate that serviceability of the SK Building met the criteria for occupant comfort during Typhoon Aere.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1031-1035

Citation:

Online since:

May 2015

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Y.H. Wang, I.H. Lee, and D.P. Wang: 2005. Typhoon induced extreme coastal surge: a case study at northern Taiwan in 1994. Journal of Coastal Research 21: 548-552.

DOI: 10.2112/03-0026.1

Google Scholar

[2] Y.L. Xu, and S. Zhan: 2001. Field measurements of Di Wang Tower during typhoon York. Journal of Wind Engineering and Industrial Aerodynamics. 89: 73-93.

DOI: 10.1016/s0167-6105(00)00029-5

Google Scholar

[3] M. M Amiri, and, M. Yahyai: 2013, Estimation of damping ratio of TV towers based on ambient vibration monitoring. Struct. Design Tall Spec. Build., 22: 862–875.

DOI: 10.1002/tal.733

Google Scholar

[4] Q. S. Li, Y.Q. Xiao. and C.K. Wong: 2005. Full-scale monitoring of typhoon effects on super tall buildings. Journal of Fluids and Structures 20, 697-717.

DOI: 10.1016/j.jfluidstructs.2005.04.003

Google Scholar

[5] ISO6897-1984: 1984. Guideline for the evaluation of the response of occupants of fixed structures, especially buildings and off-shore structures, to low-frequency horizontal motion (0. 063 to 1 Hz), International Standard Organization.

DOI: 10.3403/00134676u

Google Scholar

[6] W.H. Melbourne, and J.C.K. Cheung: 1988. Designing for serviceable accelerations in tall buildings, Proceedings of the Fourth International Conference on Tall Buildings, Hong Kong, Shanghai, pp.148-155.

DOI: 10.1016/0013-7944(88)90039-2

Google Scholar

[7] K.S. Liu, and Y. B. Tsai: 2013, Full-scale Measurements on Vibrations of a 51-story Tall Building due to a Major Earthquake and Typhoon, Applied Mechanics and Materials, Vols. 284-287, 1259-1163.

DOI: 10.4028/www.scientific.net/amm.284-287.1259

Google Scholar

[8] T.J. Chang, Y.T. Wu, H.Y. Hsu, C.R. Chu and C.M. Liao; 2003. Assessment of wind characteristics and wind turbine characteristics in Taiwan. Renewable Energy; 28: 851-71.

DOI: 10.1016/s0960-1481(02)00184-2

Google Scholar