The Evaluation of Indoor Microbial Air Quality in Two New Commissioning Higher Educational Buildings in Johor, Malaysia

Article Preview

Abstract:

The proliferation of indoor airborne microorganism in public institutional buildings such as schools and universities is often regarded as a potential health hazards to the buildings’ users. This issue is not new in Malaysia, a country with humid climate which favours the growth of microorganism. However, there is lack of research’s data, especially in higher institutional buildings in this country. The assessment of the indoor air quality is conducted in a university’s two new commissioning buildings located at Southern Peninsular of Malaysia. Both buildings utilized centralized air conditioning system. Concentrations of airborne microorganism were determined using a single-stage impacter (biosampler) as per requirement of National Institute of Occupational Safety and Health (NIOSH) Manual Analytical Method 0800. The acquired readings were compared to the standard level determined in Industry Code of Practice on Indoor Air Quality (ICOP IAQ) 2010. Other parameters such as relative humidity, temperature, and air velocity were recorded along the assessment. The mean concentrations of the total bacteria at the affected area of the two buildings are 1102.5 CFU/m3 and 813 CFU/m3 respectively and it is significantly higher compared to the maximum exposure limit of 500 CFU/m3. While, the mean concentration of total fungi at the affected area for two buildings are 805.7 CFU/m3 and 509 CFU/m3 respectively which are both higher than the reading of outdoors and unaffected indoor area although slightly lower than the maximum exposure limit of 1000 CFU/m3. This study provides a glance of the poor indoor microbiological air quality in new higher institutional buildings in this humid region.

You have full access to the following eBook

Info:

* - Corresponding Author

[1] Yau, Y. H., Chew, B. T., & Saifullah, A. Z. A. (2012). Studies on the indoor air quality of Pharmaceutical Laboratories in Malaysia. International Journal of Sustainable Built Environment, 1(1), 110-124.

DOI: 10.1016/j.ijsbe.2012.07.005

Google Scholar

[2] Takigawa, T., Wang, B. L., Sakano, N., Wang, D. H., Ogino, K., & Kishi, R. (2009).

Google Scholar

[3] Gots, R. E., Layton, N. J., & Pirages, S. W. (2003). Indoor health: background levels of fungi. AIHA journal, 64(4), 427-438.

DOI: 10.1080/15428110308984836

Google Scholar

[4] Pastuszka, J. S., Kyaw Tha Paw, U., Lis, D. O., Wlazło, A., & Ulfig, K. (2000). Bacterial and fungal aerosol in indoor environment in Upper Silesia, Poland. Atmospheric Environment, 34(22), 3833-3842.

DOI: 10.1016/s1352-2310(99)00527-0

Google Scholar

[5] Dangman, K. H., Schenck, P., DeBernardo, R. L., Yang, C. S., Bracker, A., & Hodgson, M. J. (2004).

Google Scholar

[6] Favero, M. S., Puleo, J. R., Marshall, J. H., & Oxborrow, G. S. (1966). Comparative levels and types of microbial contamination detected in industrial clean rooms. Applied microbiology, 14(4), 539-551.

DOI: 10.1128/am.14.4.539-551.1966

Google Scholar

[7] Abidin, A. S. Z., Leman, A. M. & Noraini, N. M. R. (2011). Background Level of Microbe in New Office Building. Journal of OCCUPATIONAL, 25.

Google Scholar

[8] Department of Occupational Safety and Health. Ministry of Human Resources. Industry code of practice on indoor air quality. 2010. JKKP DP (S) 127/379/4-39.

Google Scholar

[9] Krause, M., Geer, W., Swenson, L., Fallah, P., & Robbins, C. (2006).

Google Scholar

[10] Maclntosh, D. L., Brightman, H. S., Baker, B. J., Myatt, T. A., Stewart, J. H., & McCarthy, J. F. (2006). Airborne fungal spores in a cross-sectional study of office buildings. Journal of occupational and environmental hygiene, 3(7), 379-389.

DOI: 10.1080/10543400600760438

Google Scholar

[11] Lee, J. A., Johnson, J. C., Reynolds, S. J., Thorne, P. S., & O'shaughnessy, P. T. (2006). Indoor and outdoor air quality assessment of four wastewater treatment plants. Journal of occupational and environmental hygiene, 3(1), 36-43.

DOI: 10.1080/15459620500455380

Google Scholar

[12] Ramachandran, G., Adgate, J. L., Banerjee, S. et al. (2005).

Google Scholar

[13] Tranter, D. C., Wobbema, A. T., Norlien, K., & Dorschner, D. F. (2009). Indoor allergens in Minnesota schools and child care centers. Journal of occupational and environmental hygiene, 6(9), 582-591.

DOI: 10.1080/15459620903103454

Google Scholar

[14] Lian, K. S., Nila, I., and Ahmad, R. (2007). Sources of Indoor Air Quality Problem in a New Hospital in Malaysia., The 6th International Conference on Indoor Air Quality, Ventilation & Energy Conservation in Buildings, Sendai, Japan.

Google Scholar

[15] Ismail, S.H., Deros, B.M. and Leman, A.M. (2010). Indoor Air Quality Issues for Non-Industrial Workplace. IJRRAS 5 (3).

Google Scholar

[16] Wardah, A.R., Hafizi, R., Siti Nurdijati, B. and Salleh, B. (2011). Incidence and remediation of fungi in sick building in Malaysia- A case study. Aerobiologia, 28(2), 275-283.

DOI: 10.1007/s10453-011-9226-y

Google Scholar

[17] Hussin, N.H.M., Sann, L.M., Shamsudin, M.N., and Hashim, Z. (2011). Characterization of Bacteria and Fungi Bioaerosol in the Indoor Air of selected Primary Schools in Malaysia. Indoor and Built Environment, 20(6), 607-617.

DOI: 10.1177/1420326x11414318

Google Scholar

[18] Sekhar, S. C., Tham, K. W., and Cheong, K. W. (2003). Indoor air quality and energy performance of air‐conditioned office buildings in Singapore. Indoor air, 13(4), 315-331.

DOI: 10.1111/j.1600-0668.2003.00191.x

Google Scholar

[19] Luksamijarulkul, P., Panya, N., Sujirarat, D., and Thaweboon, S. (2009). Microbial air quality and standard precaution practice in a hospital dental clinic. Journal of the Medical Association of Thailand= Chotmaihet thangphaet, 92, S148.

Google Scholar

[20] Daisey, J. M., Angell, W. J., & Apte, M. G. (2003). Indoor air quality ventilation and health symptoms in schools: an analysis of existing information. Indoor Air, 13, 53–64.

DOI: 10.1034/j.1600-0668.2003.00153.x

Google Scholar

[21] Nugroho, A. M., Ahmad, M. H., & Ossen, D. R. (2007). A preliminary study of thermal comfort in Malaysia's single storey terraced houses. Journal of Asian Architecture and Building Engineering, 6(1), 175-182.

DOI: 10.3130/jaabe.6.175

Google Scholar

[22] Sulaiman, Z., & Mohamed, M. (2011). Indoor air quality and sick building syndrome study at two selected libraries in Johor Bahru, Malaysia. Environment Asia, 4(1), 67-74.

Google Scholar

[23] Wong, L. T., Mui, K. W., Hui, P. S., Chan, W. Y., & Law, A. K. Y. (2008). Thermal Environmental Interference with Airborne bacteria and Fungi Level in Air-Conditioning Offices. Indoor and Built Environment, 17(2), 2.

DOI: 10.1177/1420326x08089260

Google Scholar

[24] Green, C.F.; Scarpino, P.V.; Gibbs, S.G. (2003) Assessment and modeling of indoor fungal and bacterial concentrations. Aerobiologia, 19: 159-169.

DOI: 10.1023/b:aero.0000006531.35387.bd

Google Scholar