Comparative Study of Wear Behavior of Multilayer Coatings for Human Hip Prosthesis

Article Preview

Abstract:

Artificial hip joints have been implanted throughout the world into patients suffering from disabling hip joint disease, to restore their painless joint function. This means replacing the femoral head and acetabular socket with artificial prosthetic components. In order to obtain artificial implants with enhanced physical, chemical, mechanical, biological and tribological properties resulting in the accelerated self-adaptation of human body and long term performance, it is necessary to combine the advantages of materials with various properties; biocompatibility, bioactivity, excellent corrosion resistance, high fatigue and tensile strength, low modulus of elasticity, coefficient of friction, and high wear resistance. The present work focuses on investigating the wear rate of multi-layer coatings for different combinations in order to reduce the wear rate of the prosthesis. Three different combinations of multilayer coating were deposited by plasma arc spraying technique on titanium. It was found that the multi-layer coating consists of Alumina as a primary coating and Zirconia as the secondary coating provides lower wear rate and higher hardness compared to other combinations which would give optimal performance and thereby increasing its longevity.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

528-533

Citation:

Online since:

August 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] H. Fouad, RabehElleithy, High density polyethylene/graphite nano-composites for total hip joint replacements: Processing and in vitro characterization, Journal of the mechanical behavior of biomedical materials. 4 (2011) 1376-1383.

DOI: 10.1016/j.jmbbm.2011.05.008

Google Scholar

[2] Steven M. Kurtz, SeviKocagoz, Christina Arnholt, Roland Huet, Advances in zirconia toughned alumina biomaterials for total joint replacement, Journal of the mechanical behavior of biomedical materials. 3 (2014) 107-116.

DOI: 10.1016/j.jmbbm.2013.03.022

Google Scholar

[3] Guocheng Wang, fanhaoMeng, Chuanxian Ding, Paul K Chu, Xuanyong Liu, Microstructure, bioactivity and osteoblast behavior of monolithic zirconia coating with nanostructured surface, ActaBiomaterialia. 6 (2010) 990-1000.

DOI: 10.1109/inec.2010.5425174

Google Scholar

[4] H. Gul, F. Kilic, S. Aslan, A. Alp, H. Akbulut, Characteristics of electro-co-deposited Ni-Al203nano-particle reinforced metal matrix composite (MMC) coatings, Wear. 267 (2009) 976-990.

DOI: 10.1016/j.wear.2008.12.022

Google Scholar

[5] Prem V. Pavoor, Brian P. Gearing, OrhunMuratoglu, Robert E. Cohen, AnujBellare, Wear reduction of orthopedic bearing surfaces using polyelectrolyte multilayer nanocoatings, Biomaterials. 27 (2006) 1527-1533.

DOI: 10.1016/j.biomaterials.2005.08.022

Google Scholar

[6] A. Vadiraj , & M. Kamaraj, Characterization of fretting fatigue damage of PVD TiN coated biomedical titanium alloys, Surface and Coatings Technology. 200 (2006) 4538-4542.

DOI: 10.1016/j.surfcoat.2005.03.036

Google Scholar

[7] C. Richard, C. Kowandy, J. Landoulsi, M. Geetha, H. Ramasawmy, Corrosion and wear behavior of thermally sprayed nano ceramic coatings on commercially pure Titanium and Ti–13Nb–13Zr substrates, Tribology of Hard Coatings. 28 (2010) 115-123.

DOI: 10.1016/j.ijrmhm.2009.08.006

Google Scholar

[8] S. Sathish, M. Geetha, S. T. Aruna, N. Balaji, K.S. Rajam, & R. Asokamani, Studies on plasma sprayed bi-layered ceramic coating on bio-medical Ti-13Nb-13Zr alloy, Ceramics International. 37 (2011) 1333-1339.

DOI: 10.1016/j.ceramint.2010.12.012

Google Scholar

[9] B.S. Bal, & M.N. Rahaman, Orthopedic applications of silicon nitride ceramics, Acta Biomaterialia. 8 (2012) 2889-2898.

DOI: 10.1016/j.actbio.2012.04.031

Google Scholar

[10] T. Sun, & M. Wang, Mechanical performance of apatite/TiO2 composite coatings formed on Ti and NiTi shape memory alloy, Applied Surface Science. 255 (2008) 404-408.

DOI: 10.1016/j.apsusc.2008.06.070

Google Scholar

[11] G. Perumal , M. Geetha, R. Asokamani, & N. Alagumurthi, Wear studies on plasma sprayed Al2O3-40wt% 8YSZ composite ceramic coating on Ti-6Al-4V alloy used for biomedical applications, Wear. 311 (2014) 101-113.

DOI: 10.1016/j.wear.2013.12.027