Effect of Flow Velocity of Sea Water on Corrosion Rate of Low Carbon Steel

Article Preview

Abstract:

The purpose of this research is to investigate the corrosion rate of low carbon steel in saline environment. The influence of variety of conditions that represent the actual conditions in practice such as the flow velocity and solution composition, particularly Na+, Cl- and SO4-2, content were performed. Weight loss test of low carbon steel in the lab was conducted to determine the corrosion rate data in stagnant and flowing seawater for comparison to investigate the effect of flow velocity of sea water on the corrosion behavior of the low carbon steel. Results show that the corrosion rate of low carbon steel is increased by increasing the flow of seawater, but at very high velocities the corrosion rate was recorded to be decreased. XRD results show that the corrosion products contain both Fe2O3 and FeO(OH).

You might also be interested in these eBooks

Info:

Periodical:

Pages:

232-236

Citation:

Online since:

October 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Raja V. S., Baligidad R. G., and Shankar Rao V., Effect of Carbon on Corrosion Behavior of Fe3 Al Inter-metallic's in 0. 5 N Sulfuric acid , Journal of Corrosion Science, Vol. 33, p.521–533, (2002).

DOI: 10.1016/s0010-938x(01)00084-1

Google Scholar

[2] Batis G., and Rakanta E"Corrosion of Steel Reinforcement Due to Atmospheric Pollution", Journal of Cement and Concrete Composite, Vol. 27, p.269 – 275, (2005).

DOI: 10.1016/j.cemconcomp.2004.02.038

Google Scholar

[3] Takasaki S., and Yamada Y., Effects of Temperature and Aggressive Anions on Corrosion of Carbon Steel in Potable Water, Journal of Corrosion Science, Vol. 49, pp.240-247, (2007).

DOI: 10.1016/j.corsci.2006.05.035

Google Scholar

[4] Wall F. D., Martinez M. A., and Missert N. A., Characterizing Corrosion Behavior Under Atmospheric Conditions Using Electrochemical Techniques, Journal of Corrosion Science, Vol. 47, pp.17-32, (2005).

DOI: 10.1016/s0010-938x(03)00081-7

Google Scholar

[5] Corvo F., and Minotas J., Changes in Atmospheric Corrosion Rate Caused by Chloric Ions Depending on Rain Regime, Journal of Corrosion Science, Vol. 47, p.883 – 892, (2005).

DOI: 10.1016/j.corsci.2004.06.003

Google Scholar

[6] Garcia K.E. and et al H., Lost Iron and Iron Converted in to Rust in Steels Submitted to Dry- Wet Corrosion Process, Journal of Corrosion Science, Vol. 50, pp.763-772, (2008).

DOI: 10.1016/j.corsci.2007.09.003

Google Scholar

[7] Kim Uh Ch, et al Dependency of Single Phase FAC of Carbon Steel and Low Alloy Steels for NPP System Piping on pH, Orifice Distance and Material,. Nucl Eng Technol, Vol. 37, p.375–84, (2005).

Google Scholar

[8] Owens AD et al, Boiler Feed Water Pipe Failure by Flow Assisted Chelant corrosion. Eng Fail Anal, Vol. 9, p.235–43, (2002).

Google Scholar

[9] P.V. Seheers, The Effects of Flow Velocity and pH on the Corrosion Rate of Mild Steel in A Synthetic Minewater, J. S. Afr. Inst. Min. Metall., vol. 92, 110, pp.275-281, (1992).

Google Scholar

[10] Chexal VK., et al "Flow-Accelerated Corrosion of Pressure Vessels in Fossil Plants. Int J Pres Ves Pip, 77, p.81–89, (2000).

Google Scholar

[11] A. Taher, G. Jarjoura and G. J. Kipouros, The Effect of Sulphate on the Electrochemical Behaviour of a Cu-Ni-Fe alloy(C70600), J. of Corr. Sci. and Eng., 12, pp.42-42, (2010).

DOI: 10.1149/ma2007-01/11/512

Google Scholar