Laser Scanning Vibrometry and Holographic Interferometry Applied to Vibration Study

Article Preview

Abstract:

The applications of high performance materials in the aerospace and in the automotive technology in the next years need to develop new vibration study, nondestructive testing, predictive maintenance and industrial control methods.The Laser Scanning Vibrometry and Holographic Interferometry methods of vibration study and nondestructive testing by modal analysis are described. The Laser Scanning Vibrometer PSV 400 is made by Polytec GmbH and the PSV software reconstructs the 3D model of the measured micro-deformation of the object. The holographic laser system HLS-3 from Lumonics Inc. has 100 MW ruby laser peak power and 30 ns pulse width.Using mechanical excitation to induce a measurable vibration, the Laser Scanning Vibrometry and Holographic Interferometry modal analysis measurements show up the vibrational signatures and the damaged areas of the objects made by high performance materials - polymers, composites.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

303-311

Citation:

Online since:

October 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Breaban F., Allemon P., Hazebrouck R., Deffontaine A. - Analyse modale de vibrations d'un disque par interférométrie holographique à double exposition synchronisée", Actes du 6e congrès de la Société Française d'Acoustique (SFA) et l, Association Belge des Acousticiens (ABAV), CFA Lille, 2002, pp.308-311.

Google Scholar

[2] Breaban, F., Allemon, P., Hazebrouck, R., Deffontaine, A. - Vibration Response of Perforated Thin Plates verified by Double Pulse Holographic Interferometry, Proceedings of the X-th Conference on Mechanical Vibrations, Timisoara 23-24 mai 2002, pp.95-100.

DOI: 10.1121/1.426361

Google Scholar

[3] Opto & Laser Europe, oct. 2002, pp.25-27.

Google Scholar

[4] Polytec Scanning Vibrometer Manuals, 76337 Waldbronn, Germany.

Google Scholar

[5] Breaban F., Defer D., Duthoit B., Contrôle non destructif par Vibrométrie Laser par rapport aux techniques Holographiques, Colloque CMOI, Nantes, 17-21 nov. 2008, Rev. Contr. Ess. Mes., dec. 2008, pp.29-30.

Google Scholar

[6] Cârlescu V., Breaban F., Olaru D., Prisacaru G., A Technique for Dynamic Characterization of Dielectric Elastomers, 2nd Int. Conf. MECAHITECH'10 Bucharest, 23-24 Sept. (2010).

Google Scholar

[7] Breaban F., Carlescu V., Olaru D., Prisacaru Gh., Coutte J., Laser Scanning Vibrometry Applied to Non-Destructive Testing of Electro-Active Polymers, U.P.B. Sci. Bull., Series D, 73 (2011) 171-180.

Google Scholar