Researches on NOx Emissions from the Test Bench Testing of a Post Combustion Burner

Article Preview

Abstract:

The more and more restrictive environment requirements in the field of pollutant emissions of co-generative plants are imposing researches related to the more efficient work of those related to the post combustion facility. The paper presents the results of a post combustion burner achieved on a test bench, when it idling operates on natural gas mixed with air or with burned gases of a gas turbine. The modeling of the measured emissions, led to NOx concentrations in ambient air that are below the limits imposed by the in force regulations related to air quality and are correlated to the real time measured data.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

303-308

Citation:

Online since:

June 2016

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2016 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Ene Barbu E. et al.: The Influence of Inlet Air Cooling and Afterburning on Gas Turbine Cogeneration Groups Performance, Gas Turbines - Materials, Modeling and Performance, Dr. Gurrappa Injeti (Ed. ), ISBN: 978-953-51-1743-8, InTech (2015).

DOI: 10.5772/59002

Google Scholar

[2] Cammarata G. et al.: Reacting flows in post-combustion burners of a heat recovery steam generator, 5th European Thermal-Sciences Conference, The Netherlands (2008).

Google Scholar

[3] Catalano L. et al.: Ansaldo Post-Firing System for Combined-Cycle Plants, Proceedings of 31st Meeting on Combustion, section IX-%, pp.1-5, June 17-20, 2008, Torino, Italy.

Google Scholar

[4] Directive 2008/50/EC of the EUROPEAN PARLIAMENT and of the COUNCIL of 21 May 2008 on ambient air quality and cleaner air for Europe.

DOI: 10.12775/pyel.2012.005

Google Scholar

[5] Cretu M: Modelling and simulation of the pollutant species transport in open spaces, PhD thesis, chapter, 6, pp.135-139, University Politehnica of Bucharest (2012).

Google Scholar

[6] Information on http: /www. eclipsenet. com/products/fluefire/ [Accessed 19. 01. 2016].

Google Scholar

[7] Barbu E. et al.: Arzator de postardere multimodular de combustibil gazos, OSIM Patent 126, 229 (2012).

Google Scholar

[8] Information on https: /www. ec. gc. ca/inrp-npri/default. asp?lang=En&n=30D8D456-1 [Accessed 11. 11. 2015].

Google Scholar

[9] Information on http: /www. woelfel. de/fileadmin/user_upload/www. woelfel. de/brochueren/immissionsschutz/IMMI_Schadstoffmodul_EN. pdf [Accessed 10. 02. 2016).

Google Scholar

[10] Romanian Law 104/2011 on ambient air quality Directive 2008/50/EC of the EUROPEAN PARLIAMENT and of the COUNCIL of 21 May 2008 on ambient air quality and cleaner air for Europe.

DOI: 10.12775/pyel.2012.005

Google Scholar

[11] Macak J.: Evaluation of Gas Turbine Startup and Shutdown Emissions for New Source Permitting, Mostardi Platt Environmental Conference, 2006, paper 546, session EI-2a, Oakbrook, Illinois, USA.

Google Scholar