A New Proposed Method to Reverse Engineer a Residual Limb for Prosthetic Socket - Procedure, Advantages and Challenges

Article Preview

Abstract:

A prosthetic replaces any missing human body part visibly and also aims to resume the normal functionality of the part. Reverse engineering extracts information from a present model or available design and develops a new model using advanced CAD tools. Nowadays the reverse engineered part can be combined with rapid prototyping by various software and integration of CAD-CAM platforms. In this paper, a new method to reverse engineer the residual limb information for lower limb amputees, in order to use it for analyzing and developing a prosthetic socket by scanning and developing a CAD model is proposed. Along this are discussed, the advantages and challenges. This work falls in the emerging field of interdisciplinary engineering, combining medical and advanced mechanical engineering on a humanitarian platform

You might also be interested in these eBooks

Info:

Periodical:

Pages:

558-563

Citation:

Online since:

September 2016

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2016 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Linlin Zhang, Ming Zhu, Ling Shen, Feng Zheng., 2013. Finite element analysis of contact interface between trans femoral stump and prosthetic socket, 35th annual international conference of the IEEE EMBS.

DOI: 10.1109/embc.2013.6609739

Google Scholar

[2] Imran Ali, Ramesh kumar, Yogendra Singh., 2014 Finite element Modelling and analysis of transtibial prosthetic socket, Global Journal Inc. (US).

Google Scholar

[3] Prasanna Kumar Lenka, Amit Roy., 2011 Analysis of transtibial prosthetic socket material using finite element method, J. Biomedical Science and Engineering.

Google Scholar

[4] ChitreshNayak, Amit Singh, Himanshu Chaudhary, Customised prosthetic socket fabrication using 3D scanning and printing, MalviyA National Institute of technology.

Google Scholar

[5] David Moinina, Hugh Herr, A variable Impedance Prasthetic Socket for trans tibialaamputee designed from magnetic resonance imaging data, Journal of prosthesis and orthot.

Google Scholar

[6] Rajesh Surapureddy,. 2014 Predicting pressure distribution between transfemoral prosthetic socket and residual lomb using finite element analysis, UNF thesis and dissertations.

DOI: 10.1504/ijecb.2016.10002681

Google Scholar

[7] A.N. Sinha, Arun D. Udai., 2007. Development of artificial limb surface using reverse engineering method, Proceedings of International Conference on Advances in Machine Design & Industry Automation, January 10 – 12, , College of Engineering, Pune, India.

Google Scholar

[8] Giorgio Colombo, Massimiliano Bertetti, Daniele Bonacini, GraziaMagrassi., 2006. Reverse engineering and rapid prototyping techniques to innovate prosthesis socket design, Three dimensional image Capture and applications VII, SPIE Vol. 6056, (2006).

DOI: 10.1117/12.644175

Google Scholar

[9] Ha Van Vo, Stephanie Rossman, ZsaquezFlucker and R. Radharamanan, Comparison of shear stress acting in the sockets of typical mobile and immobile ankle prosthesis using FEA, School of engineering, Mercer University, Macon, GA 31207.

Google Scholar

[10] Kahtan al-Khazraji, Jawad Kadhim, PaymanSahbadahmed., 2012. Tensile and Fatigue characteristics of lower limb prosthetic socket made from composite materials, Proceedings of the 2012 international conference on industrial engineering and operations management.

Google Scholar