A Earth Fault Section Identification Method Based on ANN

Article Preview

Abstract:

The method to discriminate the fault within or beyond the protective zone according to the signals with high frequency detected in protection has problem with low reliability when the resistance of earth fault is high. The transient voltage with low frequency detected in protection can reflect the size of fault intensity approximately, and the transient voltage with high frequency detected in protection in internal fault is bigger than that in external fault when the size of fault intensity is same. The high frequency transient voltage and low frequency transient voltage detected in protection are chosen as inputs and fault section as outputs for training and testing the neural network for fault identification in the UHVDC transmission line, fault section can be identified when input fault characteristic data to the trained model. A variety of transmission line earth fault situation are simulated by PSCAD, and this earth fault section identification method based ANN shows satisfactory performance, even the fault resistance is high.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 1006-1007)

Pages:

913-918

Citation:

Online since:

August 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Zhang Baohui,Hao Zhiguo,Zhi qianBo.Development of relay protection for smart grid(1): new principles of fault distinction[J].Automation of Eltectric Power System,2010,30(1):l-9.

Google Scholar

[2] Wang Gang,Luo Jianbin,Li Haifeng,et a1.Transient energy protection for ±800kV UHVDC transmission lines[J].Automation of Eltectric Power System,2010,34(1):28—32.

Google Scholar

[3] Shu Hongchun,Tian Xincui,Zhang Guangbin.Protection for±800kV HVDC transmission lines using pole wave transient[J].Proceedings of the CSEE,201l,31(22):96—104.

Google Scholar

[4] Shu Hongchun,Tian Xincui,Dong Jun.Identification between internal and external faults of ±800kV HVDC transmission lines based on voltage correlation[J].Proceedings of the CSEE,2012,32(4):15l-160.

Google Scholar

[5] Shu Hongchun,Tian Xincui,DongJun.Simulation and analyses for Yun—Guang ±800kV HVDC transmission line protection system[J].Proceedings of the CSEE,2011,31(4):179-188.

Google Scholar

[6] Shu Hongchun,An Na,DongJun.Fractal algorithm of faults identification for HVDC transmission lines[J].Automation of Electric Power System,2012,36(12):49-54.

Google Scholar

[7] Shu Hongchun,Liu Kezhen,Zhang Guangbin,et a1.±800 kV UHVDC transmission line protection based on single end electrical transient signal.

Google Scholar