Applicability Research on Evaporative Cooling Technology in Hunan Province

Article Preview

Abstract:

According to the climate conditions of Hunan province and the design parameters related to air conditioning, the energy consumption and the related characteristics of the liquid desiccant evaporative cooling system (LDECS) are compared with primary return air conditioning system. The results show that energy consumption of LDECS can be decreased by 11.78% compared to the primary return air system. LDECS has a certain degree of energy saving potential in Hunan province, especially when waste heat is available.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 1070-1072)

Pages:

1679-1683

Citation:

Online since:

December 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] The national statistics bureau of the People's Republic of China. China statistical yearbook of 2012[M]. Beijing: China statistics press, 2012. (In Chinese).

Google Scholar

[2] Building energy conservation research center of Tsinghua University. Annual development report for Chinese building energy conservation of 2013[M]. Beijing: China Architecture & Building Press, 2012. (In Chinese).

Google Scholar

[3] Chaoyi Tan, Shengyou Liu and Qin Ouyang. Design of Freezing Dehumidification-Based Radiant Air-Conditioning System for Library Reading Room [J]. Journal of Hunan University of Technology, 2012, 26(4), 37~41. (In Chinese).

Google Scholar

[4] Qionglin Peng, Yun Ling, Xuefeng Xiao, Li Fei and Chen Huan. The Intelligent Controller Design of VAV Air Conditioning System Based on Embedded Processor S3C2440A [J]. Journal of Hunan University of Technology, 2013, 27(5), 81~84. (In Chinese).

Google Scholar

[5] Xiang Huang, Fangcheng Xu and Junmei Wu. The important role of evaporative cooling air-conditioning technology in energy conservation and emissions reduction [J]. Refrigeration and Air-conditioning, 2008, 8 (4), 17~20. (In Chinese).

Google Scholar

[6] Yugang Wang, Jiaping Liu, Xiang Huang, and Yang Shaohui. Energy Saving Potential of Liquid Desiccant Evaporative Cooling System in Airmen [J]. Fluid Machinery, 2012, 40(5), 67-70. (In Chinese).

Google Scholar

[7] Yaoqing Lu. Practical heating and air conditioning design handbook (second edition) [M]. Beijing: China Architecture & Building Press, 2007. (In Chinese).

Google Scholar

[8] Yi Jiang, Xiaosong Zhang and Yonggao Yin. Construction and performance research on liquid desiccant evaporative cooling system [J]. Journal of southeast university (Natural science edition), 2006, 4 (5): 780-784. (In Chinese).

Google Scholar

[9] Xiaoyang Chen, Yi Jiang and Zhen Li. Project practice with an independent humidity control air conditioning system [J]. HV&AC, 2004(11): 103-109. (In Chinese).

Google Scholar