Performance and Operation Analysis of a Quadra Sectors Rotary Airheater Adopted by CFB Boiler

Article Preview

Abstract:

Based on the aspects of thermal properties, resistance properties, air Leakage Control and boiler output adaptability, the operation modes and their impact of a quad-sector rotary airheater adopted by a 330MWe circulating fluidized bed boiler are analyzed by tests. And the operation methods of Leakage Control System are concluded. In order to improve the reliability of rotary airheater with main and auxiliary motors, recommendations for improvement are extended.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 1070-1072)

Pages:

1764-1768

Citation:

Online since:

December 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Ming-chun Wang. Control system of leakage in rotary preheater for power generating unit. Journal of Southeast University. 28(1998) 66-68.

Google Scholar

[2] Ling Li, Bu-ting Zhang, Chun-yu Wang. Present situation and analysis of coal-fired generating units of Airheater. 2, Henan Electric Power. 2(2011) 30-31.

Google Scholar

[3] Gan-jin Chen, Ming-kun Cai. Sbwl new design technology of ljungstrom Airheater and gas-gas heater. Boiler Technology. 34(2003) 1-7, 58.

Google Scholar