Research and Develop on Series of Cryogenic Methanol Coil-Wound Heat Exchanger

Article Preview

Abstract:

A series of cryogenic methanol coil-wound heat exchangers with multi-stream and multiphase flows were researched and developed, including methanol-methanol cooler, cryogenic recycle methanol cooler, unshifted gas cooler, shifted gas cooler, feed gas cooler etc. The winding structure characteristics and the work principle of the spiral pipe bundles were elaborated to help the scientific design and calculation of coil-wound heat exchanger in cryogenic methanol field and to promote the research and development of standardization process. The major research directions and the critical scientific problems were forecasted.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 1070-1072)

Pages:

1769-1773

Citation:

Online since:

December 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Obana Hideo[Japan], XU Zhongquan(translator). Heat exchanger design manual [M]. Beijing: Petroleum Industry Press, 1982. 09.

Google Scholar

[2] Zhang Zhou-wei, Wang Ya-hong. Coil wound heat exchanger[M]. Lanzhou: Lanzhou University Press, 2014. 6.

Google Scholar

[3] Zhang Zhou-wei. The single-stream spiral wrapping cryogenic heat exchanger with vacuum insulation: China, 2011103111939[P], 2011. 09.

Google Scholar

[4] Zhang Zhou-wei. The calculation method of the design of single-stream spiral pipe heat exchanger: China, 201210297815. 1[P], 2012. 09.

Google Scholar

[5] Zhang Zhou-wei. A double-stream cryogenic spiral coil-wound heat exchanger with vacuum insulation[P]. China: 2011103156319, 2012. 05.

Google Scholar

[6] Zhang Zhou-wei. The design and calculation method for double flow spiral coil wound heat exchanger [P]. China: 201210303321. X, 2013. 01.

Google Scholar

[7] Zhang Zhou-wei. A cryogenic spiral coil-wound heat exchanger with four stream in the first stage of LNG liquefaction process[P]. China: 201110379518. 7, 2012. 05.

Google Scholar

[8] Zhang Zhou-wei. A cryogenic spiral coil-wound heat exchanger with three stream in second stage of LNG liquefaction process[P]. China: 201110376419. 3, 2012. 08.

Google Scholar

[9] Zhang Zhou-wei. A cryogenic spiral coil-wound heat exchanger in third stage of LNG liquification process[P]. China: 201110373110. 9, 2012. 08.

Google Scholar

[10] Zhang Zhou-wei. A main cryogenic spiral coil-wound heat exchanger with multi-stream mixed-refrigerant in the LNG liquefaction process[P]: China, 201110381579. 7, 2012. 08.

Google Scholar

[11] Zhang Zhou-wei. The design and calculation method for cryogenic methanol-methanol spiral coil-wound heat exchanger[P]: China, 201210519544. X, 2013-01.

Google Scholar

[12] Zhang Zhou-wei. The spiral coil-wound heat exchanger for low temperature recycled methanol cooler[P]. China: 201210548454. 3, 2013. 03.

Google Scholar

[13] Zhang Zhou-wei. The cryogenic spiral coil-wound heat exchanger for unshifted feed gas cooler, [P]. China: 201210569754. X, 2013. 04.

Google Scholar

[14] Zhang Zhou-wei. The cryogenic spiral coil wound heat exchanger for shifted feed gas cooler [P]. China: 201310000047. 3, 2013. 04.

Google Scholar

[15] Zhang Zhou-wei. The three-stream cryogenic spiral coil- wound heat exchanger for feed gas cooler [P]. China: 201310034723. 9, 2013. 05.

Google Scholar

[16] Zhang Zhou-wei. The main multi-stream coil-Wound heat exchanger for the heat recovery of cryogenic liquid nitrogen[P]. China: 201310366573. 1, 2013. 08.

Google Scholar

[17] Zhang Zhou-wei. The first-stage multi-stream heat exchanger for the heat recovery of cryogenic liquid nitrogen[P]. China: 201310387575. 9, 2013. 08.

Google Scholar

[18] Zhang Zhou-wei. The second-stage spiral coil-wound heat exchanger for the heat recovery of cryogenic liquid nitrogen[P]. China: 201310361165. 7, 2013. 08.

Google Scholar

[19] Zhang Zhou-wei. The third-stage spiral coil-wound heat exchanger for the heat recovery of cryogenic liquid nitrogen[P]. China: 201310358118. 7, 2013. 08.

Google Scholar

[20] Zhang Zhou-wei, Xue Jia-xing, Wang Ya-hong. Calculation and design method study of the coil-wound heat exchanger[J]. Advanced Materials Research, 2014, Vols. 1008-1009: 850-860.

DOI: 10.4028/www.scientific.net/amr.1008-1009.850

Google Scholar

[21] Zhang Zhou-wei, Wang Ya-hong, Xue Jia-xing. Research on cryogenic characteristics in spatial cold-shield system[J]. Advanced Materials Research, 2014, Vols. 1008-1009 : 873-885.

DOI: 10.4028/www.scientific.net/amr.1008-1009.873

Google Scholar

[22] Zhang Zhou-wei, Li Lian-bo, Li Jun. The design and caculation software for coil-wound heat exchanger[Z]. Chinese Copyright Protection Center, 201310358118. 7, 2011. 09.

Google Scholar