Equivalent P-v Model of Wind Farm Based on Measured Data

Article Preview

Abstract:

Accurate model of the wind farm is the basis for the analysis of wind power integrating grid. This paper proposed the equivalent P-v(active power-wind speed) model with K-means algorithm based on the measured operating data. An actual wind farm is adopted to verify the effectiveness of the model. The result of error comparative analysis shows that the accuracy of the model is greatly improved with the method proposed in this paper compared with the traditional model.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 1070-1072)

Pages:

233-237

Citation:

Online since:

December 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Y. H. Zhang, M. Zhou, G. Y. Li. Wind power price regulation considering wind power fluctuation. Critical Infrastructure(CRIS), 2010 5th International Conference, 2010.

DOI: 10.1109/cris.2010.5617571

Google Scholar

[2] J. K. Sethi, D. Deb, M, Malakar. Modeling of a wind turbine farm in presence of wake interactions. Energy, Automation, and Signal(ICEAS), International Conference, 2011.

DOI: 10.1109/iceas.2011.6147144

Google Scholar

[3] D. Y. Yang, L. G. Ban, Z. T. Xiang, N. Du, et al. An aggregation method of wind farm model for electromagnetic transient simulation analysis, Power Electronics and Machines in Wind Applications(PEMWA), 2012 IEEE.

DOI: 10.1109/pemwa.2012.6316356

Google Scholar

[4] J. G. Qiao, Z. X. Lu, Y. Min, J. Liu, Z. J. Xie and H. Q. Wang, New Dynamic Equivalence Method for Grid-Connected Wind Farm, Transactions of China Electrotechnical Society, vol24, pp.209-213, Apr. 2009.

Google Scholar

[5] LI Guang-yun,CHEN Xiao-hu,TANG Guo-qing.Review on equivalent modeling for large-scale wind power field[J].Journal of North China Electric Power University,2006, 33(1):42-46.

Google Scholar

[6] SUN Jian-feng,JIAO Lian-wei,WU Jun-ling,et al.Research on multi-machine dynamic aggregation in wind farm[J].Power System Technology,2004,28(7):58-61.

Google Scholar

[7] CAO Na,ZHAO Hai-xiang,CHEN Mo-zi,et al.Equivalence method of wind farm in steady-state load flow calculation[J].Power System Technology,2006,30(9):53-56.

Google Scholar

[8] YAN Gan-gui,LI Hong-bo,MU Gang,et al.Equivalent model of wind farm By Using the Equivalent Wind Speed[J].Journal of Northeast China Institute of Electric Power Engineering, 2011,31(3):13.

DOI: 10.1109/supergen.2009.5348106

Google Scholar

[9] TIAN Chun-zheng,LI Qiong-lin,SONG Xiao-kai.Modeling and analysis of the stability for the power system considering the integration of the wind farms[J].Power System Protection and Control,2009,37(19):46.

Google Scholar

[10] Fahim A M, Salem A M, Torkey F A, An efficient enhanced k-means clustering algorithm Journal of Zhejiang University Science A, Vol. 10, pp: 1626-1633, July (2006).

DOI: 10.1631/jzus.2006.a1626

Google Scholar