A New Method of Three-Phase Unbalanced Load Harmonic Current Detection

Article Preview

Abstract:

The extensive usage of power electronic equipments makes harmonic problem increasingly serious. In unbalanced three-phase system, traditional p-q, d-q method ignores the zero sequence currents, resulting in zero sequence harmonic leakage error. This article is based on the basic principle of instantaneous reactive power theory, it proposes a new type of harmonic detection algorithm, this algorithm does not need phase-locked loop nor do a matrix transformation, and can effectively avoid the zero order harmonic leakage error caused by coordinate transformation.In the end, using Matlab/Simulink environment to build models of traditional algorithm and improved algorithm .Through comparison, the simulation result shows that the improved algorithm is more accurate and more effective than the traditional one.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 1070-1072)

Pages:

726-730

Citation:

Online since:

December 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Lu Xiao Qin, Zhang Chun Jun, Zhang Xiu Feng . A new algorithm for random harmonic current detection under unbalanced three phase system. Power System Protection and Control, 2013, 41(13):94-96. (in Chinese).

Google Scholar

[2] Guo Feng Xiang. Research on Billing Management System Security [J]. Friend of Science Amateurs. 2011(20)(in Chinese).

Google Scholar

[3] Zhou Xue Feng. Harmomic Detection Method in Power Network Based on FFT Algorithm[J]. Industry and Mine Automation. 2012(03). (in Chinese).

Google Scholar

[4] R. S. Herrera, P. Salmeron, and K. Hyosung, Instantaneous reactive power theory applied to active power filter compensation: Different approaches, assessment, and experimental results, IEEE Trans. Ind. Electron., vol. 55, no. 1, p.184–196, Jan. (2008).

DOI: 10.1109/tie.2007.905959

Google Scholar

[5] R. S. Herrera and P. Salmeron, Instantaneous reactive power theory: A reference in the nonlinear loads compensation, IEEE Trans. Ind. Electron., vol. 56, no. 6, p.2015–2022, Jun. (2009).

DOI: 10.1109/tie.2009.2014749

Google Scholar

[6] H. Akagi, YKanazawa, A. Nabae. Instantaneous reactive power compensators comprising switching devices without energy storage components. IEEE Trans Ind Appl, 1984, 20(3): 625-630.

DOI: 10.1109/tia.1984.4504460

Google Scholar

[7] Yang Jun, Wang Zhaoan. A study on the comparison of two methods used to detect the harmonic currents of Three-phase circuits . transactions of china electrotechnical society. 1995, 10(2): 43-48(in Chinese).

Google Scholar

[8] LI Yang chun. Study on a new filter to suppress the zero-sequence current [J]. Power System Protection and Control,. 2010, 38(7): 92-93(in Chinese).

Google Scholar