Abstract:

With continuous expansion of the grid, the power system structure is becoming more complicated, leading to more and more uncertainty of the system. Especially, the massive integration of wind power and other renewable energy to the grid brings more challenges. In this paper, by taking use of DSR (dynamic security region) and risk assessment theory, it proposed the transient risk index calculation and integrated analysis method for wind power integration system, which was able to give quantitative indicators of the system day-ahead scheduling plan. The efficiency and practicality of theories mentioned herein were verified by standard numerical examples.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 1092-1093)

Pages:

122-126

Citation:

Online since:

March 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Gu Feng, Cao Youletu: Choice of Best Access Point for Connecting Wind Farm to Power System. Power System and Clean Energy, 2010, 26(3): 73-76.

Google Scholar

[2] Roy Billinton, Bipul Karki: Well-being Analysis of Wind Integrated Power System. IEEE Transaction on Power Systems, 2011, 26(4): 2101-2108.

DOI: 10.1109/tpwrs.2011.2138171

Google Scholar

[3] Billinton R, Allan R N: Reliability Evaluation of Power Systems. New York, NY, USA: Plenum Press, (1984).

Google Scholar

[4] Li Wenyuan: Power System Risk Assessment—model, method and application. Science Press, Beijing, China (2006).

Google Scholar

[5] Shi Wenhui, Bie Zhaohong, Wang Xifan: Applications of Markov Chain Monte Carlo in Large-scale System Reliability Evaluation. Proceedings of the CSEE, 2008, 28(4): 9-15.

DOI: 10.1049/cp:20062074

Google Scholar

[6] Zeng Yuan, YU Yixin: A Practical Direct Method for Determining Dynamic Security Region of Electronic Power System. Proceedings of the CSEE, 2003, 23(5): 24-28.

DOI: 10.1109/icpst.2002.1047606

Google Scholar

[7] Zeng Yuan, Yu Yixin, Jia Hongjie: Theoretical Explanation of Hyper-plane Boundary of Dynamic Security Region. Electrical and Computer Engineering Conference, Canadian, (2005).

DOI: 10.1109/ccece.2005.1557363

Google Scholar

[8] Liu Hui, Yu Yixin: A Comprehensive Security Control Method Based on Practical Dynamic Security Regions of Power Systems. Proceedings of the CSEE, 2003, 25(20): 31-36.

Google Scholar

[9] Yu Yixin, LuanWenpeng: Practical Dynamic Security Regions of Power Systems. Proceedings of the CSEE, 1990, 10(supp for Mathematics of Electrical Engineering).

Google Scholar

[10] Miao Weiwei, Jia Hongjie, Dong Zeyin: A Minimum Load Shedding Calculation Algorithm Based on Static Voltage Stability Region in Active Load Power Injection Space. Proceedings of the CSEE, 2012, 32(16): 44-52.

DOI: 10.1109/tencon.2011.6129252

Google Scholar