Analysis on Corona Discharge Characteristics of the Overhead Conductor

Article Preview

Abstract:

LGJ150/25 steel core aluminum stranded wires were selected as the test wires, and the aeolian vibrations which work in different cycle times of wire that is under the conditions of dry and acidic corrosion were simulated by the self-made test bed. The electronic number of corona discharge of each pre-set conductor was measured, when applying AC high voltage on the wearing wires step by step,so that the corona inception voltages of the conductors could be confirmed. And the effect of the vibration cycle times and environmental conditions on the corona discharge was researched. Taking the sum of all aluminium stands wear area of a pre-set wire as the fretting wearing capacity, the relationship between the wire wearing capacity and the corona discharge was studied. The results indicate that the corona inception voltages of the conductors decrease with the increase of the cycle times and the wires wear capacity. In general, the wear capacity of the acidic corrosion conductors is larger, and its corona inception voltage is lower. Therefore the decrease of the conductor fretting wear can effectively reduce the corona loss of transmission lines and other hazards.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 1092-1093)

Pages:

233-237

Citation:

Online since:

March 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Ziwei Zhang. Research of HV Transmission and Power Transfer Discharge Based on UV Imaging Method. North China Electric Power University master's thesis. (2007).

Google Scholar

[2] Bin Ma, Wenjun Zhou, Tao Wang, Yigong Ding. Non- uniform Electric Field Corona Discharge of the Severe Non- uniform Electric Field Based on the UV-light imaging technology. High Voltage Engineering. (32): 136~15(2006. 07).

DOI: 10.1109/ceem.2006.257947

Google Scholar

[3] Lan Chen, Xingming Bian, Fenglin Chen, Xiaobo Meng, Liming Wang, Zhicheng Guang. Method to Judge Corona Inception Voltage of AC Transmission Line Using Corona Cage High Voltage Engineering. 01(37): 85-90(2011).

DOI: 10.1109/ceidp.2010.5723958

Google Scholar

[4] Yuanpeng Liu, Wenfang Zeng, Shaohua You, Fangcheng Lv. Analysis of Corona Onset Voltage of AC Split Conductors Using Small Corona Cage, High Voltage Engineering. (37):2302-2307(2011. 9).

Google Scholar

[5] S. Karabay, F. Kaya Önder. An approach for analysis in refurbishment of existing conventional HV–ACSR transmission lines with AAAC[J]. Electric Power Systems Research. (72): 179~185(2004).

DOI: 10.1016/j.epsr.2004.03.014

Google Scholar

[6] Z.R. ZHOU, Vincent. L , Fretting Wear[M]. Beijing: Science Press, 183~188(2002).

Google Scholar

[7] Xinze Zhao, Wei Gao, Meiyun Zhao, Shaoqing Zhang. Wear Characteristics of Aluminum Cable Steel Reinforced(ACSR) under Dry and Acidic Conditions[J]. Tribology. 31(6):616~621(2011).

Google Scholar

[8] Xinze Zhao, Haijun Lao , Wei Gao. Conductor and Wear Analysis on the Wires of Aluminium Contact Steel Reinforced[J]. Lubrication Engineering. (11): 48~52(2009).

Google Scholar

[9] Xinze Zhao, Haijun Lao, Wei Gao . Analysis on the Characteristics of Wear Debris of Aluminum Steel Conductor Steel Reinforced[J]. Lubrication Engineering. (1): 59~61(2010).

Google Scholar

[10] Xinze Zhao, Qifeng Wang, Quan Zhou, Meiyun Zhao, Shaoqing Zhang. Fretting Wear Behavior of Aluminum Cable Steel Reinforced. Lubrication Engineering. 38(3): 32~35(2013).

Google Scholar